Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/76566

TítuloQuality assurance of segmental strain values provided by commercial 2-D speckle tracking echocardiography using in silico models: a report from the EACVI-ASE Strain Standardization Task Force
Autor(es)Røsner, Assami
Alessandrini, Martino
Kjønås, Didrik
Mirea, Oana
Queirós, Sandro Filipe Monteiro
D'hooge, Jan
Palavras-chaveReference Standards
Reproducibility of Results
Ventricular Function, Left
Echocardiography
Speckle tracking
In silico simulated model
2-D strain imaging
Quality assessment
Different vendors
DataNov-2021
EditoraElsevier 1
RevistaUltrasound in Medicine and Biology
Resumo(s)The aim of this study was to determine the accuracy and reproducibility of vendor-specific regional strain values by echocardiography using in silico data. Synthetic 2-D ultrasound gray-scale images of the left ventricle (LV) were generated with knowledge of the longitudinal segmental strain values from the underlying electromechanical LV model. Four of five models mimicked transmural infarctions with systolic segmental stretching in different vascular areas. Cine loops in the three apical views were synthetically generated at four noise levels. All in silico images were repeatedly analyzed by a single investigator and some by another investigator. The absolute errors varied significantly between vendors from 3.3 ± 3.1% to 11.2 ± 5.9%. The area under the curve for the identification of segmental stretching ranged from 0.80 (confidence interval: 0.77-0.83) to 0.96 (0.95-0.98). The levels of agreement for intra-investigator variability varied between -3.0% to 2.9% and -5.2% to 4.8%, and for inter-investigator variability, between -3.6% to 3.5% and -14.5% to 8.5%. Segmental strain analysis allows the identification of areas with segmental stretching with good accuracy. However, single segmental peak-strain values are not accurate and should be interpreted with caution. Nevertheless, our results indicate the usefulness of semiquantitative strain assessment for the detection of regional dysfunction.
TipoArtigo
URIhttps://hdl.handle.net/1822/76566
DOI10.1016/j.ultrasmedbio.2021.07.011
ISSN0301-5629
Versão da editorahttps://doi.org/10.1016/j.ultrasmedbio.2021.07.011
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
ARosner_UMB_accepted.pdf5,88 MBAdobe PDFVer/Abrir

Este trabalho está licenciado sob uma Licença Creative Commons Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID