Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/51782

Registo completo
Campo DCValorIdioma
dc.contributor.authorKumar, Bharath S.por
dc.contributor.authorAndrade, Renatopor
dc.contributor.authorLeal, Anapor
dc.contributor.authorSarmento, Andrépor
dc.contributor.authorPereira, Hélder Filipe Carvalhopor
dc.contributor.authorSousa, Nuno Eduardo Sevivaspor
dc.contributor.authorEspregueira-Mendes, Joãopor
dc.date.accessioned2018-03-08T11:20:18Z-
dc.date.issued2016-08-01-
dc.identifier.citationKumar, B. S., Andrade, R., Leal, A., Sarmento, A., Pereira, H., Sevivas, N., & Espregueira-Mendes, J. (2016). Surgical Adjustment of the Guide Pin to Perform a Correct Tibial Tunnel in Anatomical Anterior Cruciate Ligament Single-Bundle Reconstruction. Arthroscopy techniques, 5(4), e757-e762.por
dc.identifier.issn2212-6287-
dc.identifier.urihttps://hdl.handle.net/1822/51782-
dc.description.abstractAnatomical positioning of the graft in anterior cruciate ligament reconstruction is important to restore normal knee kinematics and prevent early joint degeneration. Inadequate position of a first attempt to place the guide pin within the center of the tibial footprint may occur. Therefore, its adjustment is important to achieve the anatomical positioning of the graft within the tibial footprint. When the guide pin exits eccentrically in an inadequate position, it is possible to correct it to the center of the footprint. A small tunnel with a 4.5-mm reamer is made and the guide pin is shifted to the center of the footprint. The center of the tunnel can be corrected until 50% and in all direction in relation to the initial drilled tunnel, without additional associated morbidity. Once the correct position of the center is achieved, the guide pin is fixed in the femoral notch roof to guarantee the accurate correction of the axis, without toggling of the guide pin inside the tunnel and metal dusting. The final tunnel is then drilled with the same size of the graft. With this technique it is possible to adjust an eccentrically misplaced guide pin to the center of the footprint without additional morbidity.por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.rightsclosedAccesspor
dc.titleSurgical Adjustment of the Guide Pin to Perform a Correct Tibial Tunnel in Anatomical Anterior Cruciate Ligament Single-Bundle Reconstructionpor
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://www.arthroscopytechniques.org/article/S2212-6287(16)00086-4/abstractpor
oaire.citationStartPagee757por
oaire.citationEndPagee762por
oaire.citationIssue4por
oaire.citationVolume5por
dc.date.updated2018-01-30T13:54:25Z-
dc.identifier.doi10.1016/j.eats.2016.03.002por
dc.subject.fosCiências Médicas::Medicina Clínicapor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technologypor
sdum.journalArthroscopy Techniquespor
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
kumar etal.pdf
Acesso restrito!
1,21 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID