Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/79544

TítuloPhage engineering for the detection of Pseudomonas aeruginosa
Autor(es)Costa, Maria João Caetano
Meneses, Luciana
Santos, Sílvio Roberto Branco
Azeredo, Joana
Pires, Diana Priscila Penso
Palavras-chavephage engineering
Pseudomonas aeruginosa
detection
bioluminescence
Data18-Jul-2022
CitaçãoCosta, Maria João; Meneses, Luciana; Santos, Sílvio Roberto Branco; Azeredo, Joana; Pires, Diana P., Phage engineering for the detection of Pseudomonas aeruginosa. VoM 2022 - Viruses of Microbes - The Latest Conquests (Program and Abstract Book). Guimarães, Portugal, June 17-22, 549, 2022.
Resumo(s)Pseudomonas aeruginosa is an opportunistic Gram-negative bacterium. Due to its high antibiotic resistance and capacity to adapt and survive in hostile conditions, P. aeruginosa is responsible for a wide range of human infections, such as surgical site infections, bacteremia, urinary tract infections, and mostly, pneumonia. In COVID-19 patients, P. aeruginosa is a common co-infecting pathogen, associated with increased disease severity and worse clinical outcomes. Considering the slow turnover of conventional diagnostic methods and the problems associated with the molecular and immunogenic methods, this study aimed at assembling a bioluminescence-based reporter phage for the fast and sensitive detection of P. aeruginosa in clinical care. Phage vB_PaeP_PE3 was genetically engineered using the yeast-based phage engineering platform. The genome of this phage was previously reduced by deleting genes with unknown function, and here, this phage genome was used as a scaffold for the insertion of the NanoLuc® luciferase. The gene encoding NanoLuc was swapped with gene gp55, encoding a hypothetical protein with unknown function. The sensitivity of this phage-based detection system was evaluated through the infection of serial dilutions of P. aeruginosa suspensions with the synthetic phage, and subsequent quantification of luminescence (in relative light units, RLU). Our data showed that the reporter phage was able to reliably detect 10^2 CFU in 1 mL of contaminated sample in less than 8 h. Overall, the NanoLuc-based reporter phage allows for the rapid and sensitive detection and differentiation of viable P. aeruginosa cells using a simple protocol, 45 h faster than culture-dependent approaches. Therefore, this phage-based detection system is a promising alternative to the common methods for the accurate detection of P. aeruginosa in clinical settings.
TipoResumo em ata de conferência
URIhttps://hdl.handle.net/1822/79544
Versão da editorahttps://www.vom2022.org/
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CEB - Resumos em Livros de Atas / Abstracts in Proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
document_55731_1.pdf127,15 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID