Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/30098

Registo completo
Campo DCValorIdioma
dc.contributor.authorCarvalho, Helderpor
dc.contributor.authorCatarino, André P.por
dc.contributor.authorRocha, A. M.por
dc.contributor.authorPostolache, Octavianpor
dc.date.accessioned2014-09-11T14:13:43Z-
dc.date.available2014-09-11T14:13:43Z-
dc.date.issued2014-06-
dc.identifier.isbn9781479929207por
dc.identifier.urihttps://hdl.handle.net/1822/30098-
dc.descriptionPublicado em "MeMeA 2014 International Symposium on Medical Measurements and Applications : proceedings", ISBN 978-1-4799-2920-7por
dc.description.abstractThis paper gives an overview of technologies and results of integration and test of textile integrated sensors and electrodes for monitoring of biosignals (electrocardiographic - ECG and electromyographic - EMG), breathing and moisture. Using a seamless jacquard knitting machine, it is possible to integrate these sensors and electrodes directly into the fabrics, which can then be used in clothing for monitoring of elderly people, in sports or in hazardous occupations. The total integration of the sensing elements and connections into the garment presents great advantages in physical as well as psychological comfort of the user. It has been shown that the measurements are of adequate quality for most of the applications. In some cases, as is the case of ECG and EMG, signals acquired are similar to those obtained using conventional electrodes.por
dc.description.sponsorshipThe authors wish to thank funding by FCT -Fundação para a Ciência e a Tecnologia, projects PEst-C/CTM/UI0264/2011, PTDC/DTP-DES/1661/2012 and project PROTACTICAL - Co-Promoção Nº Projecto: 23267, sponsored by ADIpor
dc.language.isoengpor
dc.publisherIEEEpor
dc.relationinfo:eu-repo/grantAgreement/FCT/3599-PPCDT/126905/PT-
dc.rightsopenAccesspor
dc.subjecte-textilepor
dc.subjectBiosignal monitoringpor
dc.subjectTextile sensorspor
dc.subjectTextile electrodespor
dc.subjectECGpor
dc.subjectEMGpor
dc.subjectTextilepor
dc.titleHealth monitoring using textile sensors and electrodes: an overview and integration of technologiespor
dc.typeconferencePaper-
dc.peerreviewedyespor
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6860033&refinements%3D4279791410%26sortType%3Dasc_p_Sequence%26filter%3DAND%28p_IS_Number%3A6860015%29por
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate11 - 12 Jun. 2014por
sdum.event.typeconferencepor
oaire.citationStartPage70por
oaire.citationEndPage75por
oaire.citationConferencePlaceLisboa, Portugalpor
oaire.citationTitleInternational Symposium on Medical Measurements and Applications (MeMeA 2014)por
dc.identifier.doi10.1109/MeMeA.2014.6860033por
dc.subject.fosEngenharia e Tecnologia::Outras Engenharias e Tecnologiaspor
dc.subject.wosScience & Technologypor
sdum.conferencePublicationInternational Symposium on Medical Measurements and Applications (MeMeA 2014)por
Aparece nas coleções:DET/2C2T - Comunicações em congressos internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
MeMeA2014_IEEEXplore.pdfArticle2,15 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID