Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/88660

TítuloFire behaviour of reinforced concrete slab strips strengthened with prestressed NSM-CFRP laminates
Autor(es)Azevedo, Adriana S.
Firmo, João P.
Correia, João R.
Mohammadifirouz, Reza
Barros, Joaquim A. O.
Palavras-chaveRC slabs
CFRP strengthening
NSM
Prestress
Fire behaviour
Data2023
EditoraElsevier 1
RevistaEngineering Structures
Resumo(s)Carbon fibre reinforced polymer (CFRP) composites are now widely used to strengthen reinforced concrete (RC) structures. Among the strengthening systems available, near-surface mounted (NSM)-prestressed CFRP laminates offer several advantages, as they significantly increase the load carrying capacity and also the serviceability performance of RC structures. However, as for other CFRP systems, there is a concern about their behaviour at elevated temperature and under fire exposure due to the glass transition process undergone by their polymeric components. Nevertheless, the fire performance of NSM-prestressed-CFRP strengthening systems has not yet been investigated. This paper presents an experimental study about the fire resistance behaviour of RC slab strips strengthened with prestressed NSM-CFRP laminates; the slabs were simultaneously subjected to a mechanical (fire) load and the ISO 834 fire curve, and the influence of the following parameters on their fire resistance behaviour was assessed: (i) the prestress level (0 %, 25 % and 50 % of the CFRP tensile strength), and (ii) the presence of passive fire protection, comprising up to 48 mm thick calcium silicate (CS) boards. The results obtained showed that: (i) without fire protection, the strengthening system remained effective during a very low period of fire exposure, which significantly decreased with the prestress level, from 16 min (0 %) to less than 5 min (50 %); (ii) with fire protection, even with 50 % of prestress, the strengthening system remained effective for more than 120 min; and (iii) the “critical” temperatures in the anchorages of the strengthening systems were found to be about 2.5Tg, 2.0Tg and 1.5Tg, for the prestress levels of 0 %, 25 % and 50 %, respectively, with Tg being the glass transition temperature of the adhesive.
TipoArtigo
URIhttps://hdl.handle.net/1822/88660
DOI10.1016/j.engstruct.2023.116982
ISSN0141-0296
e-ISSN1873-7323
Versão da editorahttps://www.sciencedirect.com/science/article/pii/S0141029623013974
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Fire behaviour of reinforced concrete slab strips strengthened with prestressed NSM-CFRP laminates.pdf8,96 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID