Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/80305

TítuloThermal analysis of a raft concrete foundation: a case study of a leaking ethane tank
Autor(es)Wattanapanich, Chirawat
Imjai, Thanongsak
Aosai, Pakjira
Hansapinyo, Chayanon
Figueiredo, Fábio Pereira
Garcia, Reyes
Palavras-chavereinforced concrete
raft foundation
temperature effects
finite element modelling
Data23-Jun-2022
EditoraMultidisciplinary Digital Publishing Institute
RevistaBuildings
CitaçãoWattanapanich, C.; Imjai, T.; Aosai, P.; Hansapinyo, C.; Figueiredo, F.P.; Garcia, R. Thermal Analysis of a Raft Concrete Foundation: A Case Study of a Leaking Ethane Tank. Buildings 2022, 12, 889. https://doi.org/10.3390/buildings12070889
Resumo(s)This article presents a case study on the thermal assessment of a reinforced concrete (RC) foundation exposed to low temperatures. The foundation supports a 19,500 m<sup>3</sup>-capacity tank with low-temperature (−89 °C) ethane. Icing and bubbling were observed on the tank’s surface soon after it started operations. Condensation was also observed at the bottom of the 0.8-m-depth RC slab, which raised concerns about the structural condition of the concrete. This study provides details of the field and analytical investigations conducted to assess the structural condition of the foundation. Heat transfer finite element (FE) analyses were performed to examine the concrete sections subjected to low temperatures. It was found that the ethane leakage produced a low temperature on the top side of the concrete foundation of +9.7 °C. Overall, the temperatures calculated by the FE analyses were in good agreement with actual field measurements, within a ±5% accuracy. The simplified heat transfer equation for porous media used in this study was sufficiently accurate to model the effects of the ethane leakage in the concrete foundation, provided that the ambient temperature at the site is taken into account in the analysis. The results also confirm that reinforcing bars can be neglected in the thermal analysis of massive concrete slabs. The results from the field measurements and FE analyses confirmed that the structural integrity of the RC foundation was never compromised. The approaches, methods and techniques discussed in this article are deemed suitable to solve the practical and scientific challenges involved in the thermal assessment and repairs of large special structures. Accordingly, they can serve as useful reference and guidance for engineers and practitioners working in the field of forensic engineering.
TipoArtigo
URIhttps://hdl.handle.net/1822/80305
DOI10.3390/buildings12070889
e-ISSN2075-5309
Versão da editorahttps://www.mdpi.com/2075-5309/12/7/889
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:BUM - MDPI

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
buildings-12-00889-v3.pdf25,51 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID