dc.description.abstractNowadays, different techniques are available for manufacturing full-arch implant-supported prosthesis, many of them based on an impression procedure. Nevertheless, the long-term success of the prosthesis is highly influenced by the accuracy during such process, being affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of a 3D electromagnetic motion tracking system as an acquisition method for modeling such prosthesis. To this extent, we propose an implant acquisition method at the patient mouth, using a specific prototyped tool coupled with a tracker sensor, and a set of calibration procedures (for distortion correction and tool calibration), that ultimately obtains combined measurements of the implant's position and angulation, and eliminating the use of any impression material. However, in the particular case of the evaluated tracking system, the order of magnitude of the obtained errors invalidates its use for this specific application.por
dc.description.sponsorshipThis work has been supported by FCT – Fundação para a Ciência e Tecnologia in the scope of the Ph.D. grant SFRH/BD/68270/2010 and the project EXPL/BBB-BMD/2146/2013.por
dc.language.isoengpor
dc.publisherCRC Presspor
dc.relationSFRH/BD/68270/2010por
dc.relationinfo:eu-repo/grantAgreement/FCT/COMPETE/135171/PTpor
dc.rightsopenAccesspor
dc.titleAn electromagnetic tracker system for the design of a dental superstructurepor
dc.typeconferencePaperpor
dc.peerreviewedyespor
oaire.citationConferenceDate22 - 23 June 2014por
sdum.event.titleIII International Conference on Biodental Engineeringpor
sdum.event.typeconferencepor
oaire.citationStartPage137por
oaire.citationEndPage143por
oaire.citationConferencePlacePorto, Portugalpor
dc.date.updated2021-03-31T20:13:02Z-
dc.subject.wosScience & Technology-
sdum.export.identifier10273-
sdum.conferencePublicationBiodental engineering III: proceedings of the III International Conference on Biodental Engineeringpor
sdum.bookTitleBIODENTAL ENGINEERING III-
Aparece nas coleções:DEI - Artigos em atas de congressos internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
BioDental2014_Final.pdf681,74 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID