Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/44056

TítuloAstigmatic peripheral defocus with different contact lenses: review and meta-analysis
Autor(es)Queirós, A.
Lopes-Ferreira, Daniela
González-Méijome, José Manuel
Palavras-chaveAstigmatism
Myopia progression
Peripheral defocus
Peripheral refraction
Data2016
EditoraTaylor and Francis
RevistaCurrent Eye Research
CitaçãoQueiros, A., Lopes-Ferreira, D., & Gonzalez-Meijome, J. M. (2016). Astigmatic Peripheral Defocus with Different Contact Lenses: Review and Meta-Analysis. Current Eye Research, 41(8), 1005-1015. doi: 10.3109/02713683.2015.
Resumo(s)Purpose: To review the level of relative peripheral defocus measured with different devices with potential use for myopia retention. To present comparative data of the change in astigmatic peripheral refraction with different contact lenses evaluated in different studies conducted in the same laboratory following the same methodology in myopic human eyes Methods: A joint analysis of work, carried out at the same laboratory (CEORLab) in 137 myopic subjects with different types of contact lenses (CL), was performed to obtain the tangential (FT = M − J0), sagittal (FS = M + J0), and mean (M) power refractive errors (M and J0 are the refraction vector components). Orthokeratology, standard aspheric rigid gas-permeable (RGP), experimental RGP, experimental soft CL, and different multifocal soft CL were used to induce peripheral myopic defocus (236 peripheral refraction measures). Results: Compared with values obtained in naked eye condition (baseline), only three of the eight approaches tested show statistically significant peripheral myopic defocus induction (p < 0.001) in both temporal and nasal retina (orthokeratology, experimental RGP, and Proclear multifocal CL with Add: +3.00 D). Standard aspheric RGP also produced a significant increase in myopic defocus for the FT, of about −2.00 D. The experimental soft CL, designed to mimic the peripheral performance of the experimental RGP, induced a similar effect to the standard aspheric soft CL. Conclusion: Orthokeratology, multifocal soft CL, and custom-designed RGP CL were able to generate a significant relative peripheral myopia in myopic eyes. Conversely, standard and experimental soft CL were not able to induce significant peripheral myopic and astigmatic defocus values.
TipoArtigo
URIhttps://hdl.handle.net/1822/44056
DOI10.3109/02713683.2015.1116585
ISSN0271-3683
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.119. QUEIROS_16_CER (Peripheral Astigmatism Metaanalysis).pdf346,26 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID