Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/44047

TítuloChanges in peripheral refraction, higher-order aberrations, and accommodative lag with a radial refractive gradient contact lens in young myopes
Autor(es)Pauné, Jaume
Thivent, Solène
Armengol, Jesús
Quevedo, L.
Ribeiro, Miguel António Faria
González-Méijome, José Manuel
Palavras-chavePeripheral refraction
Aberrometry
Lag of accommodation
Radial refractive gradient contact lens
Myopia
DataNov-2016
EditoraKluwer
RevistaEye and Contact Lens
CitaçãoPauné, Jaume; Thivent, Solène; Armengol, Jesús; Quevedo, Lluisa; Faria-Ribeiro, Miguel; González-Méijome, José M.Changes in Peripheral Refraction, Higher-Order Aberrations, and Accommodative Lag With a Radial Refractive Gradient Contact Lens in Young Myopes, Eye & Contact Lens: Science & Clinical Practice, 42, 6, 380-387, 2016.
Resumo(s)Purpose: To evaluate changes in the peripheral refraction (PR), visual quality, and accommodative lag with a novel soft radial refractive gradient (SRRG) experimental contact lens that produces peripheral myopic defocus. Methods: 59 myopic right eyes were fitted with the lens. The PR was measured up to 30° in the nasal and temporal horizontal visual fields and compared with values obtained without the lens. The accommodative lag was measured monocularly using the distance-induced condition method at 40 cm, and the higher-order aberrations (HOAs) of the entire eye were obtained for 3- and 5-mm pupils by aberrometry. Visual performance was assessed through contrast sensitivity function (CSF). Results: With the lens, the relative PR became significantly less hyperopic from 30° to 15° temporally and 30° nasally in the M and J0 refractive components (P,0.05). Cylinder foci showed significant myopization from 30° to 15° temporally and 30° to 25° nasally (P,0.05). The HOAs increased significantly, the CSF decreased slightly but reached statistical significance for 6 and 12 cycles per degree (P,0.05), and the accommodative lag decreased significantly with the SRRG lens (P¼0.0001). There was a moderate correlation between HOAs and CSF at medium and high spatial frequencies. Conclusion: The SRRG lens induced a significant change in PR, particularly in the temporal retina. Tangential and sagittal foci changed significantly in the peripheral nasal and temporal retina. The decreased accommodative lag and increased HOAs particularly in coma-like aberration may positively affect myopia control. A longitudinal study is needed to confirm this potential.
TipoArtigo
URIhttps://hdl.handle.net/1822/44047
DOI10.1097/ICL.0000000000000222
ISSN1542-2321
e-ISSN1542-233X
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.118. PAUNE_16_ECL (Amiopic Accomo Aberra)2.pdf456,92 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID