TítuloThe influence of rigid gas permeable lens wear on the concentrations of dinucleotides in tears and the effect on dry eye signs and symptoms in keratoconus
Autor(es)Carracedo, Gonzalo
González-Méijome, José Manuel
Martín-Gil, Alba
Carballo, Jesús
Pintor, Jesús
Palavras-chaveGP lenses
Keratoconus
Nucleotides
Dry eye
Data2016
EditoraElsevier 1
RevistaContact Lens and Anterior Eye
CitaçãoCarracedo, G., Gonzalez-Meijome, J. M., Martin-Gil, A., Carballo, J., & Pintor, J. (2016). The influence of rigid gas permeable lens wear on the concentrations of dinucleotides in tears and the effect on dry eye signs and symptoms in keratoconus. Contact Lens & Anterior Eye, 39(5), 375-379. doi: 10.1016/j.clae.2016.04.009
Resumo(s)Purpose: To evaluate the signs and symptoms of dry eye and dinucleotide secretion in tears of keratoconus patients (KC) and the potential effect of rigid gas permeable (RGP) contact lens wear. Methods: Twenty-three KC patients and forty control subjects were enrolled in this study. Signs of dry eye including tear volume, tear stability and corneal staining along with symptoms were assessed using the McMonnies questionnaire. Tears were collected using Schirmer strips, and dinucleotide concentrations in collected tears measured using high pressure liquid chromatography. Values obtained in KC and controls were compared. The effect of contact lens wear in KC was also assessed. Results: KC eyes showed a significantly lower tear volume compared to controls, shorter tear break up time (TBUT), higher corneal staining and higher McMonnies dry eye questionnaire scores (p < 0.05). When compared with non-wearers, KC contact lens wearers showed significantly higher symptoms, lower Schirmer and TBUT values (p < 0.05). Concentration of Ap4A (0.695 ± 0.304 μM vs. 0.185 ± 0.178 μM) and Ap5A (0.132 ± 0.128 μM vs. 0.045 ± 0.036 μM) were higher in KC compared to controls (p < 0.001) and only Ap4A was statistically higher in RGP wearers compared to non-wearers (0.794 ± 0.478 μM vs. 0.417 ± 0.313 μM) (p < 0.05). Conclusion: Signs and symptoms of dry eye as well as concentrations of Ap4A and Ap5A were markedly increased in KC patients compared to controls. Moreover, Ap4A and symptoms of dry eye were statistically higher in RGP wearers compared to non-wearers. This seems to indicate that factors such as RGP contact lens wear might exacerbate the clinical condition of dry eye.
TipoArtigo
URIhttps://hdl.handle.net/1822/44045
DOI10.1016/j.clae.2016.04.009
ISSN1367-0484
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.121. CARRACEDO_16_CLAE (Dinucleotides in Kconus).pdf291,67 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID