dc.identifier.citationPaiva ,A; Carvalho, H; Catarino, A.; Postolache, O.; Postolache, G.; Development of Dry Textile Electrodes for Electromiography - A comparison between knitted structures and conductive yarns, Proceedings of the ICST 2015, 9th International Conference on Sensing Technology, pp 485-489, doi: 10.1109/ICSensT.2015.7438440.por
dc.identifier.isbn978-1-4799-6314-0-
dc.identifier.issn2156-8065por
dc.identifier.urihttps://hdl.handle.net/1822/42249-
dc.description.abstractThe paper presents a practical approach concerning the design, implementation and testing of dry textile electrodes for surface electromyography purposes. Several knitted structures were designed and knitted with conductive yarns, in order to compare the influence of the fabric structure in the electrode performance. The effect of the type of conductive yarn was also studied by comparing three different yarns. It was found that the textile electrodes perform well for sEMG acquisition, with a clear depiction of the muscle activity produced. There are significant differences between the structures tested and there is also some influence from the yarn used.por
dc.description.sponsorshipThis work is supported by Portuguese National Funding, through FCT - Fundação para a Ciência e a Tecnologia, in the framework of project EHRPhysio PTDC/DTP-DES/1661/2012 and project UID/CTM/00264/2013.por
dc.language.isoengpor
dc.publisherIEEEpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147331/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/3599-PPCDT/126905/PTpor
dc.rightsopenAccesspor
dc.subjecte-textilepor
dc.subjectElectrodepor
dc.subjectElectromyographypor
dc.subjectKnittingpor
dc.subjectWearable solutions for physiotherapypor
dc.titleDevelopment of dry textile electrodes for electromiography: a comparison between knitted structures and conductive yarnspor
dc.typeconferencePaperpor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7438440por
sdum.publicationstatusinfo:eu-repo/semantics/publishedVersionpor
oaire.citationStartPage447por
oaire.citationEndPage451por
oaire.citationTitleProceedings of the IEEE ICST 2015, 9th International Conference on Sensing Technologypor
oaire.citationVolume2016-Marchpor
dc.identifier.doi10.1109/ICSensT.2015.7438440por
dc.subject.fosEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informáticapor
dc.subject.fosCiências Médicas::Biotecnologia Médicapor
dc.subject.wosScience & Technologypor
sdum.journalInternational Conference on Sensing Technologypor
sdum.conferencePublicationProceedings of the IEEE ICST 2015, 9th International Conference on Sensing Technologypor
Aparece nas coleções:DET/2C2T - Comunicações em congressos internacionais com arbitragem científica

Ficheiros deste registo: