Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/35033
Registo completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | García-Porta, Nery | por |
dc.contributor.author | Rico-del-Viejo, L. | por |
dc.contributor.author | Neves, Helena | por |
dc.contributor.author | Matos, Sofia Cláudia Peixoto de | por |
dc.contributor.author | Queirós, A. | por |
dc.contributor.author | González-Méijome, José Manuel | por |
dc.date.accessioned | 2015-05-04T14:18:02Z | - |
dc.date.available | 2015-05-04T14:18:02Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | García-Porta, Nery; Rico-del-Viejo, Laura; Neves, Helena; Peixoto-de-Matos, Sofia Claudia; Queirós, António; González-Méijome JM. Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel Contact Lens, BioMed Research International , 216932, 1, 1-13, 2015. | por |
dc.identifier.issn | 2314-6133 | por |
dc.identifier.issn | 2314-6141 | por |
dc.identifier.uri | https://hdl.handle.net/1822/35033 | - |
dc.description | "Article ID 216932" | por |
dc.description.abstract | To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three differentmultipurpose disinfecting solutions (MPDSs).Methods.Thiswas a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating. Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P < 0.05, Kruskal- Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitney U test). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P < 0.05, Kruskal-Wallis test), being higher for Synergi (Mann-Whitney U test).Thesubjective comfort was similar with the threeMPDSs. Conclusion. Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface. | - |
dc.description.sponsorship | This work has been funded by an unrestricted grant from AMO Germany GmbH and it was also partially supported by Xunta de Galicia, Spain (Predoctoral Grant) and Fundacao para a Ciencia e Tecnologia, Portugal. | por |
dc.language.iso | eng | por |
dc.publisher | Hindawi Publishing Corporation | por |
dc.rights | openAccess | por |
dc.title | Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens | por |
dc.type | article | - |
dc.peerreviewed | yes | por |
dc.relation.publisherversion | http://dx.doi.org/10.1155/2015/216932 | por |
sdum.publicationstatus | published | por |
oaire.citationStartPage | 1 | por |
oaire.citationEndPage | 13 | por |
oaire.citationTitle | BioMed research international | por |
oaire.citationVolume | 2015 | por |
dc.date.updated | 2015-04-30T14:51:42Z | - |
dc.identifier.doi | 10.1155/2015/216932 | - |
dc.identifier.pmid | 25918703 | por |
dc.subject.wos | Science & Technology | por |
sdum.journal | BioMed research international | por |
Aparece nas coleções: | CDF - OCV - Artigos/Papers (with refereeing) |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
GARCIA-PORTA_2105 (Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel CL).pdf | 2,11 MB | Adobe PDF | Ver/Abrir |