dc.contributor.author | Higueras-Esteban, Alejandro | - |
dc.contributor.author | Ortiz-Gomariz, Amanda | - |
dc.contributor.author | Gutiérrez, Ángel Ramón | - |
dc.contributor.author | Villa-Collar, César | - |
dc.contributor.author | Abad-Montes, Juan P. | - |
dc.contributor.author | Fernandes, Paulo Rodrigues | - |
dc.contributor.author | González-Méijome, José Manuel | - |
dc.date.accessioned | 2013-12-13T15:20:09Z | - |
dc.date.available | 2013-12-13T15:20:09Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 0002-9394 | por |
dc.identifier.uri | https://hdl.handle.net/1822/27013 | - |
dc.description.abstract | PURPOSE: To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. | eng |
dc.description.sponsorship | ALL AUTHORS HAVE COMPLETED AND SUBMITTED THE ICMJE FORM FOR DISCLOSURE OF POTENTIAL CONFLICTS OF INTEREST and none were reported. Supported in part by a grant from the Spanish Ministry of Health, Instituto Carlos III, Red Temitica de Investigacion Cooperativa en Salud Patologia Ocular del Envejecimiento, Calidad Visual y Calidad de Vida, Subproyecto de Calidad Visual, Madrid, Spain (RD07/0062). Involved in Design and conduct of study (A.H.-E., C.V.-C., R.G.-O., P.F., J.G.-M.); Collection, management, analysis, and interpretation of data (A.H.-E., J.G.-M., P.F.); and Preparation, review, or approval of manuscript (A.H.-E., A.O.-G., C.V.-C., R.G.-O., J.-A., P.F., J.G.-M.). | por |
dc.language.iso | eng | por |
dc.publisher | Elsevier 1 | por |
dc.rights | openAccess | por |
dc.title | Intraocular pressure after implantation of the Vsian Implantable Collamer Lens with CentraFLOW without iridotomy | por |
dc.type | article | - |
dc.peerreviewed | yes | por |
oaire.citationStartPage | 800 | por |
oaire.citationEndPage | 805 | por |
oaire.citationIssue | 4 | por |
oaire.citationTitle | American Journal of Ophthalmology | por |
oaire.citationVolume | 156 | por |
dc.date.updated | 2013-11-22T14:04:02Z | - |
dc.identifier.doi | 10.1016/j.ajo.2013.05.018 | - |
dc.identifier.pmid | 23876870 | por |
dc.subject.wos | Science & Technology | por |
sdum.journal | American Journal of Ophthalmology | por |
Aparece nas coleções: | CDF - OCV - Artigos/Papers (with refereeing) |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
5.5.89. HIGUERAS-ESTEBAN_13_AJO (ICL CentraFlow&OP).pdf | 976,35 kB | Adobe PDF | Ver/Abrir |