Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/2153

TítuloX-ray detector based on a bulk micromachined photodiode combined with a scintillating crystal
Autor(es)Rocha, J. G.
Schabmueller, C. G. J.
Ramos, N. F.
Lanceros-Méndez, S.
Costa, Manuel F. M.
Evans, A. G. R.
Wolffenbuttel, R. F.
Correia, J. H.
Palavras-chaveX-ray
Bulk micromachined photodiode
Scintillator
Data2003
EditoraIOP Publishing
RevistaJournal of micromechanics and microengineering
Citação"Journal of micromechanics and microengineering". Bristol : Institute of Physics Publishing, ISSN 0960-1317. 13 (2003). p. S45-S50.
Resumo(s)This paper reports the design, fabrication, assembly and testing of a x-ray detector based on a bulk micromachined photodiode (BMMPD) with a cavity filled with a scintillating crystal. The x-ray photons that reach the detector are first converted to visible light by the scintillating crystal. The visible light is then detected by the BMMPD, producing an electric current with value proportional to the incident x-ray intensity. Tests were performed using two x-ray setups: an experimental one and a professional one. The first was powered with a maximum voltage of 35kV, and a current ranging to 1mA and the second was powered with voltages from 40kV to 60kV and currents ranging from 10mA to 55mA.
TipoArtigo
URIhttps://hdl.handle.net/1822/2153
DOI10.1088/0960-1317/13/4/307
ISSN0960-1317
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CDF - FCD - Artigos/Papers (with refereeing)
DEI - Artigos em revistas internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
jm3407.pdf306,56 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID