Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Exposto, Bruno Fernandes | - |
dc.contributor.author | Pinto, J. G. | - |
dc.contributor.author | Pedrosa, Delfim Duarte Rolo | - |
dc.contributor.author | Monteiro, Vítor Duarte Fernandes | - |
dc.contributor.author | Gonçalves, Henrique | - |
dc.contributor.author | Afonso, João L. | - |
dc.date.accessioned | 2012-11-22T14:19:10Z | - |
dc.date.available | 2012-11-22T14:19:10Z | - |
dc.date.issued | 2012-10 | - |
dc.identifier.isbn | 978 -1-4673-2420-5 | - |
dc.identifier.issn | 1553-572X | por |
dc.identifier.uri | https://hdl.handle.net/1822/20909 | - |
dc.description.abstract | In this paper are presented experimental and simulation results of a developed Current-Source Three-Phase Shunt Active Power Filter compensating the currents of a non-linear load. The Shunt Active Power Filter controller, described in detail along the paper, relies in the p-q Theory to calculate the reference compensation currents and to regulate the DC-link inductance current. The regulation of the active filter DC-link inductance current is done consuming sinusoidal currents in phase with the system voltages. The performance and the dynamic behavior of the Shunt Active Power Filter using Periodic Sampling Modulation Technique was assessed first through several computer simulations, and then through the analysis of experimental results obtained with a developed laboratory prototype. Thereby, in this paper are presented several obtained results that show the correct operation of a Current-Source Three-Phase Shunt Active Power Filter using the Periodic-Sampling Modulation Technique. | por |
dc.description.sponsorship | Fundação para a Ciência e a Tecnologia (FCT) | por |
dc.language.iso | eng | por |
dc.publisher | IEEE | por |
dc.relation | info:eu-repo/grantAgreement/FCT/5876-PPCDTI/104569/PT | - |
dc.rights | openAccess | por |
dc.title | Current-source shunt active power filter with periodic-sampling modulation technique | por |
dc.type | conferencePaper | por |
dc.peerreviewed | yes | por |
sdum.publicationstatus | published | por |
oaire.citationStartPage | 1274 | por |
oaire.citationEndPage | 1279 | por |
oaire.citationConferencePlace | Montreal, Canada | por |
oaire.citationTitle | 38th Annual Conference of the IEEE Industrial Electronics Society – IECON2012 | por |
dc.identifier.doi | 10.1109/IECON.2012.6388555 | por |
dc.subject.wos | Science & Technology | por |
sdum.journal | IEEE Open Journal of the Industrial Electronics Society | por |
sdum.conferencePublication | 38th Annual Conference of the IEEE Industrial Electronics Society – IECON2012 | por |
Aparece nas coleções: | DEI - Artigos em atas de congressos internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
IECON_2012_CSI_PS.pdf | 773,05 kB | Adobe PDF | Ver/Abrir |