Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/20020

TítuloDevelopment of braided fibrous materials for retrofitting non-loadbearing masonry walls
Autor(es)Cunha, Fernando Eduardo Macedo
Rana, S.
Vasconcelos, Graça
Fangueiro, Raúl
Abreu, S.
Palavras-chaveMasonry walls
Retrofitting braided structure
Flexural properties
Ductility
DataJun-2012
Resumo(s)The present work reports the development of novel retrofitting materials based on braided fibrous structures for the non-load bearing masonry walls. Three different types of braided structure were produced namely (1) simple braids made of polyester yarns, (2) braids made of polyester yarns and axially reinforced with glass fibres and (3) braids made of polyester yarns and axially reinforced with carbon fibres. Three masonry wall specimens were built with traditional perforated clay bricks, embedding these braided structures within the mortar paste in specific mesh like configuration. Besides that, another wall containing glass/epoxy laminates was also fabricated in order to compare the performance of braided structures with the commonly used glass/epoxy laminates. The masonry wall specimens were characterized for flexural properties using four point load configuration and the experimental results showed that the best ductile behaviour was achieved with the braided structure having carbon fibre core. This demonstrates the suitability of this type of retrofitting material in sustaining the structure of masonry walls after occurrence of a seismic event, preventing sudden collapse and incurred losses.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/20020
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:DET/2C2T - Comunicações em congressos internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
6_2012 Development of Braided Fibrous Materials for Retrofitting Non-loadbearing Masonry Walls.pdf
Acesso restrito!
6_2012 Development of Braided Fibrous Materials for Retrofitting Non-loadbearing Masonry Walls515,43 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID