dc.description.abstractPurpose: The aim of the present study was to analyse the quality and quantity of the tear film in a young, healthy and non-contact lens-wearing population with measurements taken in the morning and in the afternoon to establish if changes exist in these parameters. Methods: In a controlled laboratory setting, morning and afternoon clinical parameters of tear film were assessed. Schirmer test, tear meniscus height, break-up time and non-invasive break-up time were measured in 51 normal subjects on the same day for each individual. Results: Tear volume showed no significant changes during the day but tear film stability was significantly reduced at the end of the day (p < 0.001), demonstrating that tear film stability is affected by the time of day. Conclusion: Researchers and clinicians might wish to consider these differences when comparisons are made between studies and populations and also when the same patient is observed over periods. Fluorescein instillation can affect the measurements of tear stability in subjects with poor quality tear filmpor
dc.language.isoengpor
dc.publisherWiley-Blackwellpor
dc.rightsrestrictedAccesspor
dc.subjectDiurnal variationpor
dc.subjectTear filmpor
dc.subjectFluoresceinpor
dc.subjectStabilitypor
dc.subjectQuantification of tearspor
dc.titleComparison of the tear film clinical parameters in two different times of the daypor
dc.typearticlepor
dc.peerreviewedyespor
sdum.publicationstatuspublishedpor
oaire.citationStartPage557por
oaire.citationEndPage562por
oaire.citationIssue6por
oaire.citationTitleClinical and Experimental Optometrypor
oaire.citationVolume94por
dc.identifier.doi10.1111/j.1444-0938.2011.00647.xpor
dc.identifier.pmid21883458por
dc.subject.wosScience & Technologypor
sdum.journalClinical and Experimental Optometrypor
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Comparison of the tear film clinical parameters at.pdf
Acesso restrito!
Documento principal212,77 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID