Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/1482

Registo completo
Campo DCValorIdioma
dc.contributor.authorPereira, Maria Olívia-
dc.contributor.authorMorin, P.-
dc.contributor.authorVieira, M. J.-
dc.contributor.authorMelo, L. F.-
dc.date.accessioned2005-05-06T15:52:27Z-
dc.date.available2005-05-06T15:52:27Z-
dc.date.issued2002-01-
dc.identifier.citation"Letters in applied microbiology". ISSN 0266-8254. 34:1 (2002) 22-26.eng
dc.identifier.issn0266-8254por
dc.identifier.urihttps://hdl.handle.net/1822/1482-
dc.description.abstractAims: The understanding of the dynamics of surface microbial colonization with concomitant monitoring of biofilm formation requires the development of biofilm reactors that enable direct and real-time evaluation under different hydrodynamic conditions. Methods and Results: This work proposes and discusses a simple flow cell reactor that provides a means to monitoring biofilm growth by periodical removing biofilm-attached slides for off-line, both non-destructive and destructive biofilm analyses. This is managed without the stoppage of the flow, thus reducing the contamination and the disturbance of the biofilm development. With this flow cell, biofilm growth and respiratory activity can be easily followed, either in well-defined laboratory conditions or in an industrial environment. Conclusions, Significance and Impact of the Study: The reproducible and typical biofilm development curves obtained, validated this flow cell and confirmed its potential for different biofilm-related studies, which can include biocidal treatment.eng
dc.description.sponsorshipInstituto de Biotecnologia e Química Fina(IBQF).por
dc.language.isoengeng
dc.publisherBlackwell Publishingeng
dc.rightsopenAccesseng
dc.titleA versatile reactor for continuous monitoring of biofilm properties in laboratory and industrial conditionseng
dc.typearticleeng
dc.peerreviewedyeseng
oaire.citationStartPage22por
oaire.citationEndPage26por
oaire.citationIssue1por
oaire.citationVolume34por
dc.identifier.doi10.1046/j.1472-765X.2002.01030.xpor
dc.identifier.pmid11849487por
dc.subject.wosScience & Technologypor
sdum.journalLetters in Applied Microbiologypor
Aparece nas coleções:CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2002-22[1].pdf148,13 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID