Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/90250

Registo completo
Campo DCValorIdioma
dc.contributor.authorSilva, Bárbarapor
dc.contributor.authorAmorim, Ana Ritapor
dc.contributor.authorFaria, Valdemar Filipe Leiraspor
dc.contributor.authorSeabra, Euricopor
dc.contributor.authorSilva, Luís F.por
dc.contributor.authorBraga, A. C.por
dc.contributor.authorViana, Ruipor
dc.date.accessioned2024-03-28T12:16:40Z-
dc.date.issued2021-06-
dc.identifier.isbn978-3-030-79167-4-
dc.identifier.issn2195-4356-
dc.identifier.urihttps://hdl.handle.net/1822/90250-
dc.description.abstractThe BioBall device, developed for wrist function rehabilitation, allows the execution of movements with a greater level of control. A component was added to make it possible to read the range of motion of the patient’s wrist. Thus, this project came up intending to evaluate the performance and suitability of the BioBall device for wrist function rehabilitation. To this end, a technical evaluation was performed in order to verify the consistency and accuracy of BioBall. Technical tests consisted of amplitude readings taken by the device, either in automatic or manual mode, “Passive Exercise” and “Physical Exercise” respectively. From the results obtained in this analysis it was concluded that the BioBall device, besides functioning correctly, can collect the angular data with consistency and it is suitable to follow the evolution of a patient's rehabilitation. In order to evaluate whether the BioBall device performs reproducible and repeatable range of motion measurements, a test-retest was performed on healthy subjects (with the space of one week). The maximum amplitude of each wrist movement of the participants was measured. The results of the statistical analysis showed that, although there is some variation in the amplitudes obtained between the test and the retest, the device has good reliability in measuring the range of motion of the wrist.por
dc.description.sponsorshipFCT - Fundação para a Ciência e a Tecnologia(UIDP/04077/2020)por
dc.language.isoengpor
dc.publisherSpringerpor
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP%2F04077%2F2020/PTpor
dc.rightsrestrictedAccesspor
dc.subjectBioBall devicepor
dc.subjectMovementpor
dc.subjectRehabilitationpor
dc.subjectWristpor
dc.titlePerformance evaluation of the BioBall device for wrist rehabilitation in adults and young adultspor
dc.typeconferencePaperpor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007/978-3-030-79168-1_13por
oaire.citationStartPage129por
oaire.citationEndPage140por
dc.date.updated2024-03-25T16:10:17Z-
dc.identifier.eissn2195-4364-
dc.identifier.doi10.1007/978-3-030-79168-1_13por
dc.date.embargo10000-01-01-
dc.identifier.eisbn978-3-030-79168-1-
dc.subject.wosScience & Technology-
sdum.export.identifier14770-
sdum.journalLecture Notes in Mechanical Engineeringpor
sdum.conferencePublicationINNOVATIONS IN MECHATRONICS ENGINEERINGpor
sdum.bookTitleInnovations in Mechatronics Engineeringpor
Aparece nas coleções:CAlg - Artigos em livros de atas/Papers in proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Artigo_ICIE.pdf
Acesso restrito!
373,39 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID