dc.description.abstractThe stability of non-compliant masonry buildings often depends on adequate reinforcement measures, expecting detailed structural assessment and reinforcement using proper techniques. Structural assessment of masonry buildings with poor building practices is a key issue in hilly regions in general that requires prompt attention. This paper addresses the seismic assessment of code-deficient unreinforced masonry (URM) buildings and their strengthened counterparts using a confined masonry (CM) structure, located in a hilly region in seismic zone IV of India. By estimating stress parameters, the seismic behavior of the buildings has been evaluated with the help of SAP2000 software and identified corresponding deficient elements of the structures. Intent of the present research is to explore the scope of improvement in structural safety of URM, taking CM as a better alternative focused to hilly areas. For this analysis linear static and dynamic methods have been used being a usual method for the analysis of seismic effects. Analysis reveals that tensile and shear stresses exceed the permissible limits (IS code- 1905:1989) at all floors in case of URM construction for height 9 m (G+ 3) which is within limit as all floors for a building of 15 m (G+ 5) in case of CM construction. In this case stresses (tensile and shear) exceed on ground floor only which needs to safe guard as the time of design. A overall, CM structure is found a better alternative for constructing moderate rise building in hilly areas.por
dc.description.sponsorship- (undefined)por
dc.language.isoengpor
dc.publisherSpringerpor
dc.rightsembargoedAccess (1 Year)por
dc.subjectCode-deficient masonry buildingspor
dc.subjectConfined masonry structurespor
dc.subjectEngineering demand parameterspor
dc.subjectLinear dynamic analysispor
dc.subjectLinear static analysispor
dc.subjectSeismic assessmentpor
dc.titleSeismic performance of confined versus unreinforced masonry buildings on hilly slopes using linear static and dynamic analysis approachespor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://link.springer.com/article/10.1007/s13369-023-08046-7por
oaire.citationStartPage13839por
oaire.citationEndPage13869por
oaire.citationIssue10por
oaire.citationVolume48por
dc.date.updated2024-02-05T20:43:28Z-
dc.identifier.doi10.1007/s13369-023-08046-7por
dc.date.embargo2025-01-01-
sdum.export.identifier13132-
sdum.journalArabian Journal for Science and Engineeringpor
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
ROHIT_SEISMIC_PAPER.pdf
  Até 2025-01-01
6,5 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID