dc.description.abstractSeveral studies on different techniques can be found on retrofitting existing unreinforced masonry (URM) walls using varieties of materials ranging from reinforced plaster, grout and epoxy injection to fibre-reinforced polymers. Still, there is a significant lack of experimental data that consider using a material such as oriented strand board (OSB) timber panels, which can be easily sourced around the globe, and are considered to be economical and sustainable. Hence, this paper presents the first stage of a multi-phase experimental investigation into the possibility of retrofitting URM walls using OSB panels. An experimental programme with full-scale testing is expensive, therefore small-scale testing such as the approach presented here is ideal to provide insight when proposing a new retrofit technique. In this paper, flexural strength in the form of four-point bending tests has been obtained on three plain masonry prisms and six OSB retrofitted specimens (615 x 215 x 102.5 mm). The effectiveness of the proposed OSB panel retrofit techniques has been assessed in terms of flexural strength, out-of-plane load capacity and displacement. It was observed that the application of the OSB panel at the back of a masonry prism greatly influenced the out-of-plane behaviour of the retrofitted specimen by increasing its flexural capacity and also by preventing its quasi-brittle collapse.por
dc.description.sponsorship- (undefined)por
dc.language.isoengpor
dc.publisherICE Publishingpor
dc.rightsrestrictedAccesspor
dc.subjectAnchors & anchoragespor
dc.subjectBrickwork & masonrypor
dc.subjectStrength & testing of materialspor
dc.titleOut-of-plane testing of masonry walls retrofitted with oriented strand board timber panelspor
dc.typearticle-
dc.peerreviewedyespor
oaire.citationStartPage403por
oaire.citationEndPage417por
oaire.citationIssue5por
oaire.citationVolume174por
dc.date.updated2024-02-02T21:02:51Z-
dc.identifier.doi10.1680/jstbu.19.00095por
dc.date.embargo10000-01-01-
dc.subject.wosScience & Technology-
sdum.export.identifier13021-
sdum.journalProceedings of the Institution of Civil Engineers-Structures and Buildingspor
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2021_S&B_174_5_Out-of-plane testing of masonry walls retrofitted with oriented strand board timber panels.pdf
Acesso restrito!
3,05 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID