Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/73904

Registo completo
Campo DCValorIdioma
dc.contributor.authorBen Hassine, Amirapor
dc.contributor.authorRaouafi, Noureddinepor
dc.contributor.authorMoreira, Felisminapor
dc.date.accessioned2021-09-06T13:43:09Z-
dc.date.available2021-09-06T13:43:09Z-
dc.date.issued2021-08-25-
dc.identifier.citationBen Hassine, Amira; Raouafi, Noureddine; Moreira, Felismina, Novel electrochemical molecularly imprinted polymer-based biosensor for Tau protein detection. Chemosensors, 9(9), 238, 2021por
dc.identifier.urihttps://hdl.handle.net/1822/73904-
dc.description.abstractA novel electrochemical biosensor based on a molecularly imprinted polymer (MIP) was developed for the impedimetric determination of Tau protein, a biomarker of Alzheimers disease (AD). Indeed, a recent correlation between AD symptoms and the presence of Tau proteins in their aggregated form made hyperphosphorylated Tau protein (Tangles) a promising biomarker for Alzheimers diagnosis. The MIP was directly assembled on a screen-printed carbon electrode (C-SPE) and prepared by electropolymerization of 3-aminophenol (AMP) in the presence of the protein template (p-Tau-441) using cyclic voltammetry. The p-Tau-441 protein bound to the polymeric backbone was digested by the action of the proteolytic activity of proteinase K in urea and then washed away to create vacant sites. The performances of the corresponding imprinted and non-imprinted electrodes were evaluated by electrochemical impedance spectroscopy. The detection limit of the MIP-based sensors was 0.02 pM in PBS buffer pH 5.6. Good selectivity and good results in serum samples were obtained with the developed platform. The biosensor described in this work is a potential tool for screening Tau protein on-site and an attractive complement to clinically established methodologies methods as it is easy to fabricate, has a short response time and is inexpensive.por
dc.description.sponsorship0624_2IQBIONEURO_6_E, 2QBioneuro, Impulso de una red de I + i en química biológica para diagnóstico y tratamiento de enfermedades neurológicas EP-INTERREG V A España Portugal (POCTEP).por
dc.language.isoengpor
dc.publisherMDPIpor
dc.rightsopenAccesspor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/por
dc.subjectElectrochemical biosensorpor
dc.subjectMIPspor
dc.subjectTau proteinpor
dc.subjectSerumpor
dc.subjectAlzheimer diseasepor
dc.titleNovel electrochemical molecularly imprinted polymer-based biosensor for Tau protein detectionpor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.mdpi.com/2227-9040/9/9/238por
dc.commentsCEB54585por
oaire.citationStartPage238por
oaire.citationIssue9por
oaire.citationVolume9por
dc.date.updated2021-08-31T17:18:02Z-
dc.identifier.eissn2227-9040por
dc.identifier.doi10.3390/chemosensors9090238por
dc.subject.fosCiências Naturais::Ciências Biológicaspor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersion-
dc.subject.wosScience & Technologypor
sdum.journalChemosensorspor
oaire.versionAMpor
Aparece nas coleções:CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
document_54585_1.pdf1,7 MBAdobe PDFVer/Abrir

Este trabalho está licenciado sob uma Licença Creative Commons Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID