dc.contributor.authorScorpio, Michelangelopor
dc.contributor.authorCiampi, Giovannipor
dc.contributor.authorRosato, Antoniopor
dc.contributor.authorMaffei, Luigipor
dc.contributor.authorMasullo, Massimilianopor
dc.contributor.authorAlmeida, Manuela Guedes depor
dc.contributor.authorSibilio, Sergiopor
dc.date.accessioned2021-04-15T18:56:33Z-
dc.date.issued2020-
dc.identifier.citationScorpio, M., Ciampi, G., Rosato, A., Maffei, L., Masullo, M., Almeida, M., & Sibilio, S. (2020). Electric-driven windows for historical buildings retrofit: Energy and visual sensitivity analysis for different control logics. Journal of Building Engineering, 31, 101398. doi: https://doi.org/10.1016/j.jobe.2020.101398por
dc.identifier.issn2352-7102por
dc.identifier.urihttps://hdl.handle.net/1822/71895-
dc.description.abstractThis paper uses the dynamic simulation software Transient System Simulation Tool to analyze the benefits of using dynamic electrical-driven glazing to refurbish the windows of historical buildings from an energy, environmental and visual points of view. For the visual analysis, Transient System Simulation Tool and Radiance were coupled. A south oriented office within the Abbey of San Lorenzo ad Septimum, located in Aversa (southern Italy), was considered for the simulations. The simulations were performed considering five window control strategies, two liquid crystal based electrical-driven glazing (able to switch faster than 1 s from an opaque to a transparent state) and two simulation switching times (1 h and 15 min). The simulation results associated with the electric -driven windows were compared to those obtained for a conventional double Low-E glazing window, highlighting that: (i) the use of the examined dynamic glazing can help to improve both the energy efficiency as well as the internal visual comfort, (ii) the effects of the control strategy are strongly related to the thermal and visual characteristics of the dynamic window and (iii) by reducing the switching time of the window, it is possible to improve the energy saving as well as the comfort inside the office.por
dc.description.sponsorship- (undefined)por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.rightsrestrictedAccesspor
dc.subjectElectric-driven smart windowpor
dc.subjectEnergy and environmental analysispor
dc.subjectVisual performancepor
dc.subjectTRNSYSpor
dc.subjectRadiancepor
dc.titleElectric-driven windows for historical buildings retrofit: Energy and visual sensitivity analysis for different control logicspor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S2352710219309349por
oaire.citationVolume31por
dc.date.updated2021-04-15T15:01:13Z-
dc.identifier.doi10.1016/j.jobe.2020.101398por
dc.date.embargo10000-01-01-
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
dc.subject.wosScience & Technology-
sdum.export.identifier5826-
sdum.journalJournal of Building Engineeringpor
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Electric-driven windows for historical buildings retrofit_Michelangelo Scorpio .pdf
Acesso restrito!
2,07 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID