dc.description.abstractThe work presented in this paper deals with the development of a solution for structural masonry walls to be used in zones with different seismic hazard and also a solution for enclosure walls for replacement of traditional cavity walls. A key concern on modern construction is sustainability, particularly with respect to energy efficient buildings, as energy consumption of buildings represents a significant share of the total consumption of energy. The novel clay masonry unit proposed here ensures an appropriate thermal and mechanical performance. Besides the description of the optimization process to obtain a proper thermal performance, the paper addresses mechanical validation based on a set of experimental tests carried out on units and masonry walls under uniaxial compressive loading. Additionally, a set of in-plane cyclic tests were carried out on masonry walls in order to assess the performance of the system under seismic loading. The results indicate that the proposed masonry unit leads to adequate thermal and mechanical behavior.por
dc.description.sponsorship- (undefined)por
dc.language.isoengpor
dc.publisherElsevier Science Ltdpor
dc.rightsopenAccesspor
dc.subjectClay brick unitspor
dc.subjectMasonry wallspor
dc.subjectThermalpor
dc.subjectMechanical propertiespor
dc.subjectIn-plane loadingpor
dc.subjectIn-plane resistancepor
dc.titleVertically perforated clay brick masonry for loadbearing and non-loadbearing masonry wallspor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0950061810001303por
oaire.citationStartPage2317por
oaire.citationEndPage2330por
oaire.citationIssue11por
oaire.citationVolume24por
dc.date.updated2020-10-25T17:36:30Z-
dc.identifier.doi10.1016/j.conbuildmat.2010.04.010por
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
dc.subject.wosScience & Technology-
sdum.export.identifier7338-
sdum.journalConstruction and Building Materialspor
oaire.versionAMpor
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Vertically perforated claybrick masonry for load bearing and non-load bearing masonry walls.pdfAuthor's Accepted Manuscript695,32 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID