Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/67388

TítuloDetection of the Prostate Cancer Biomarker PCA3 with Electrochemical and Impedance-Based Biosensors
Autor(es)Soares, Juliana Coatrini
Soares, Andrey Coatrini
Rodrigues, Valquiria Cruz
Melendez, Matias Eliseo
Santos, Alexandre Cesar
Faria, Eliney Ferreira
Reis, R. M.
Carvalho, Andre Lopes
Oliveira, Osvaldo N.
Palavras-chaveAntigens, Neoplasm
Biomarkers, Tumor
Cell Line, Tumor
DNA, Single-Stranded
Dielectric Spectroscopy
Humans
Male
Nanotubes, Carbon
Prostate
Prostate-Specific Antigen
Prostatic Neoplasms
RNA, Long Noncoding
Biosensing Techniques
Biosensors prostate cancer
PCA3
Impedance spectroscopy
EIS
DNA
biosensors
prostate cancer
Data18-Dez-2019
EditoraAmerican Chemical Society
RevistaACS Applied Materials & Interfaces
CitaçãoSoares, J. C., Soares, A. C., Rodrigues, V. C., Melendez, M. E., et. al.(2019). Detection of the Prostate Cancer Biomarker PCA3 with Electrochemical and Impedance-Based Biosensors. ACS Applied Materials & Interfaces, 11(50), 46645-46650
Resumo(s)Diagnosis of prostate cancer via PCA3 biomarker detection is promising to be much more efficient than with the prostatic specific antigens currently used. In this study, we present the first electrochemical and impedance-based biosensors that are capable of detecting PCA3 down to 0.128 nmol/L. The biosensors were made with a layer of PCA3-complementary single-stranded DNA (ssDNA) probe, immobilized on a layer-by-layer (LbL) film of chitosan (CHT) and carbon nanotubes (MWCNT). They are highly selective to PCA3, which was confirmed in impedance measurements and with polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS). Using information visualization methods, we could also distinguish between cell lines expressing the endogenous PCA3 long noncoding RNA (lncRNA) from cells that did not contain detectable levels of this biomarker. Since the methods involved in fabrication the biosensors are potentially low cost, one may hope to deploy PCA3 tests in any laboratory of clinical analyses and even for point-of-care diagnostics.
TipoArtigo
URIhttps://hdl.handle.net/1822/67388
e-ISBN1944-8252
DOI10.1021/acsami.9b19180
ISSN1944-8244
Versão da editorahttps://pubs.acs.org/doi/abs/10.1021/acsami.9b19180
Arbitragem científicayes
AcessoAcesso restrito autor
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
soares2019.pdf
Acesso restrito!
343,85 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID