Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/67284

Registo completo
Campo DCValorIdioma
dc.contributor.authorHlaili, Manelpor
dc.contributor.authorHaddouk, Amirapor
dc.contributor.authorKhlifi, Khaoulapor
dc.contributor.authorHfaiedh, Mecherguipor
dc.contributor.authorMonteiro, Vítor Duarte Fernandespor
dc.contributor.authorAfonso, João L.por
dc.date.accessioned2020-10-06T09:27:15Z-
dc.date.available2020-10-06T09:27:15Z-
dc.date.issued2020-
dc.identifier.citationHlaili M., Haddouk A., Khlifi K., Hfaiedh M., Monteiro V., Afonso J.L. (2020) Three-Phase Smart Energy Meter for Grid-Connected PV Installations. In: Afonso J., Monteiro V., Pinto J. (eds) Sustainable Energy for Smart Cities. SESC 2019. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, vol 315. Springer, Cham. https://doi.org/10.1007/978-3-030-45694-8_22por
dc.identifier.isbn978-3-030-45693-1-
dc.identifier.issn1867-8211-
dc.identifier.urihttps://hdl.handle.net/1822/67284-
dc.description.abstractHigh levels of solar energy are a good orientation for the development of grid-connected power converters used in the interface of photovoltaic (PV) installations with the power grid. In this case, in order to define control strategies and the respective tariffs, the injected power into the grid must be accounted using an energy meter. Therefore, in this paper, the implementation of a three-phase smart energy meter for PV installations is presented, ensuring the registration of the electrical energy supplied to the grid. This three-phase energy meter consists of Hall-effect sensors, used to adapt the high voltages and currents with the analog circuits of the signal conditioning, which is connected to a DSP. The developed energy meter ensures data acquisition and processing and, based on that, the energy calculation and standardization in real time. As presented along the paper, a detailed metrology analysis was developed to identify the smart meter metrological characteristics. Through the experimental validations, it was possible to validate the main features of the developed smart energy meter for grid-connected PV installations.por
dc.description.sponsorshipThis work has been supported by FCT – Fundação para a Ciência e Tecnologia within the Project Scope: UID/CEC/00319/2019. This work is financed by the ERDF – European Regional Development Fund through the Operational Programme for Competitiveness and Internationalisation – COMPETE 2020 Programme, and by National Funds through the Portuguese funding agency, FCT – Fundação para a Ciência e a Tecnologia, within project SAICTPAC/0004/2015 – POCI – 01–0145–FEDER–016434.por
dc.language.isoengpor
dc.publisherSpringerpor
dc.relationUID/CEC/00319/2019por
dc.relationSAICTPAC/0004/2015por
dc.rightsopenAccesspor
dc.subjectDSPpor
dc.subjectEnergy meterpor
dc.subjectMetrological analysispor
dc.subjectPhotovoltaicpor
dc.titleThree-phase smart energy meter for grid-connected PV installationspor
dc.typeconferencePaperpor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007%2F978-3-030-45694-8_22por
oaire.citationStartPage281por
oaire.citationEndPage290por
oaire.citationVolume315 LNICSTpor
dc.date.updated2020-09-26T05:39:51Z-
dc.identifier.doi10.1007/978-3-030-45694-8_22por
dc.identifier.eisbn978-3-030-45694-8-
dc.subject.fosEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informáticapor
sdum.export.identifier7276-
sdum.journalLecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering (LNICST)por
oaire.versionAMpor
Aparece nas coleções:CAlg - Artigos em livros de atas/Papers in proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
SESC_3F_FINAL_rp.pdfAccepted Manuscript185,23 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID