Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/67227

TítuloEnhanced ectasia detection using corneal tomography and biomechanics
Autor(es)Mendes, José Ferreira
Lopes, Bernardo T.
Correia, Fernando Faria
Salomão, Marcella Q.
Barros, Sandra Rodrigues
Ambrósio, Renato
Palavras-chaveAdult
Area Under Curve
Case-Control Studies
Corneal Diseases
Corneal Topography
Dilatation, Pathologic
Female
Humans
Male
Middle Aged
Retrospective Studies
Sensitivity and Specificity
Diagnostic Techniques, Ophthalmological
Data2019
EditoraElsevier 1
RevistaAmerican Journal of Ophthalmology
Resumo(s)PURPOSE: To test the accuracy of the Tomographic and Biomechanical Index (TBI) for ectasia detection in an independent population from the original study. DESIGN: Retrospective case-control study. METHODS: SUBJECTS: Patients were grouped according to clinical diagnosis including corneal topography (front-surface curvature): Normal group, including 1 eye randomly selected from 312 patients with normal corneas; Keratoconus group, including 1 eye randomly selected from 118 patients with keratoconus; a nonoperated ectatic eye from 57 patients with very asymmetric ectasia (57 eyes, VAE-E group), and the nonoperated fellow eye with normal topography (57 eyes, VAE-NT group). MAIN OUTCOME MEASURES: The ability of TBI to distinguish normal and ectatic corneas; and comparison with other indexes, including the Belin/Ambro´sio Deviation Index (BAD-DI) and the Corvis Biomechanical Index (CBI), considering the areas under receiver operating characteristic curves (AUCs). RESULTS: The AUC of the TBI was statistically higher than all other tested parameters (DeLong, P < .001). Considering all cases, the cut-off value of 0.335 for the TBI provided a sensitivity of 94.4% and a specificity of 94.9% (AUC [ 0.988; 95% confidence interval [CI] 0.982–0.995). Considering the VAE-NT group, optimized TBI cut-off value of 0.295 provided a sensitivity of 89.5% and a specificity of 91.0% (AUC [ 0.960; 95% CI 0.937–0.983). CONCLUSION: The TBI was more accurate than all parameters tested for differentiating normal from ectatic corneas. The TBI may epitomize ectasia susceptibility and distinguish cases with fruste disease from true unilateral cases among the eyes with normal-topography VAE.
TipoArtigo
URIhttps://hdl.handle.net/1822/67227
DOI10.1016/j.ajo.2018.08.054
ISSN0002-9394
e-ISSN1879-1891
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Ferreira-mendes-2019-Enhanced-ectasia-detection-using-co.pdf
Acesso restrito!
1,44 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID