Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/66891

Registo completo
Campo DCValorIdioma
dc.contributor.authorTorres, A.por
dc.contributor.authorAraújo, Ana S.por
dc.contributor.authorPereira, C.por
dc.contributor.authorSantos, C.por
dc.contributor.authorVivas, D.por
dc.contributor.authorPinhão, I.por
dc.contributor.authorSilva, J.por
dc.contributor.authorBrito, J.por
dc.contributor.authorPereira, J.por
dc.contributor.authorDurães, L.por
dc.contributor.authorRibeiro, Paulopor
dc.contributor.authorMelo, T.por
dc.contributor.authorColim, Ana S.por
dc.contributor.authorCarneiro, P.por
dc.date.accessioned2020-09-09T14:16:19Z-
dc.date.issued2019-
dc.identifier.issn2198-4182-
dc.identifier.urihttps://hdl.handle.net/1822/66891-
dc.description.abstractThe workers’ safety and wellbeing is the key to achieve higher levels of productivity and efficiency. An adequate lighting is one of the factors that influences the workplace and consequently, the comfort and satisfaction of the workers. This study aims to assess the lighting quality at seven work sections in a granite company. Three illuminance measurements were done with a luximeter, one with natural light and two at nightfall (with and without shadows). By studying their illuminance and luminance levels, it was perceivable the existence of lighting problems in all workplaces studied. Proven the inefficient lightning system, two experiments were run for the six workplaces. To the seventh section, as it is different from the others, a different approach was used. The results showed that with an implementation of roller shutters, 14 luminaires were enough to guarantee the necessary illuminance level. Without Dundee Roller Shutters, the number of luminaires needed was 15. To the seventh section it is recommended the utilization of a local lamp. The importance of lighting conditions is discussed, and the results obtained from illuminance measurements are presented so that improvements in the production area can be implemented.por
dc.description.sponsorshipThis work has been supported by FCT –Fundação para a Ciência e Tecnologia within the Project Scope: UID/CEC/00319/2019.por
dc.language.isoengpor
dc.publisherSpringer International Publishing AGpor
dc.relationUID/CEC/00319/2019por
dc.rightsrestrictedAccesspor
dc.subjectErgonomicspor
dc.subjectGranite manufacturingpor
dc.subjectIlluminancepor
dc.subjectLuminancepor
dc.titleLighting assessment at workplaces in a granite manufacturing companypor
dc.typebookPartpor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007%2F978-3-030-14730-3_57por
oaire.citationStartPage529por
oaire.citationEndPage537por
oaire.citationVolume202por
dc.date.updated2020-08-17T10:00:26Z-
dc.identifier.doi10.1007/978-3-030-14730-3_57por
dc.date.embargo10000-01-01-
sdum.export.identifier5937-
sdum.journalStudies in Systems, Decision and Controlpor
oaire.versionAMpor
Aparece nas coleções:CAlg - Livros e capítulos de livros/Books and book chapters

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
SHO2019_paper_40.pdf
Acesso restrito!
614,94 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID