Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/5793

Registo completo
Campo DCValorIdioma
dc.contributor.authorJorge, Jorge-
dc.contributor.authorQueirós, A.-
dc.contributor.authorGonzález-Méijome, José Manuel-
dc.contributor.authorFernandes, Paulo Rodrigues-
dc.contributor.authorAlmeida, José B.-
dc.contributor.authorParafita, Manuel A.-
dc.date.accessioned2006-11-16T16:10:03Z-
dc.date.available2006-11-16T16:10:03Z-
dc.date.issued2005-07-
dc.identifier.citation"Ophthalmic and physiological optics". ISSN 1040-5488. 25:4 (July 2005) 340-345.eng
dc.identifier.issn1040-5488eng
dc.identifier.urihttps://hdl.handle.net/1822/5793-
dc.description.abstractThe purpose of this study was to compare refractions measured with an autorefractor and retinoscopy in cycloplegic and non-cycloplegic eyes. The objective refractions were performed in 199 right eyes from 199 healthy young adults with a mean age of 21.6 ±2.66 years. The measurements were performed first without cycloplegia and repeated 30 minutes later with cycloplegia. Data were analyzed using Fourier decomposition of the power profile. More negative values of component M and J0 were give by non-cycloplegic autorefraction compared to cycloplegic autorefraction (p<0.001). However more positive values were given by non-cycloplegic autorefraciton regarding to the J45 vector, althought this differences were not statistically significant (p=0.233). Regarding retinoscopy, more negative values of component M where obtained with non-cycloplegic retinoscopy (p<0.001); for the cylindrical vectors J0 and J45 the retinoscopy without cycloplegic yields more negative values (p= 0.234; p= 0.112, respectively). Accepting that differences between cycloplegic and non-cycloplegic retinoscopy are only due to accommodative response, present results confirm that when performed by an experienced clinician, retinoscopy is a more reliable method to obtain objective start point for refraction under non-cycloplegic conditions.eng
dc.language.isoengeng
dc.publisherBlackwell Publishingeng
dc.rightsopenAccesseng
dc.subjectAstigmatismeng
dc.subjectAutorefractoreng
dc.subjectRetinoscopyeng
dc.subjectRefractive errorseng
dc.subjectCycloplegiceng
dc.subjectNon-cycloplegic refractioneng
dc.subjectcycloplegic and non-cycloplegic refractionpor
dc.titleThe influence of cycloplegic in objective refractioneng
dc.typearticlepor
dc.peerreviewedyeseng
sdum.number4eng
sdum.pagination340-345eng
sdum.publicationstatuspublishedeng
sdum.volume25eng
oaire.citationStartPage340por
oaire.citationEndPage345por
oaire.citationIssue4por
oaire.citationVolume25por
dc.identifier.doi10.1111/j.1475-1313.2005.00277.xpor
dc.identifier.pmid15953119por
dc.subject.wosScience & Technologypor
sdum.journalOphthalmic and physiological opticspor
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
The influence of cycloplegic in objective refraction.pdfarticle102,46 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID