Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/55098

TítuloValidation study of a Kinect based body imaging system
Autor(es)Bragança, Sara
Arezes, P.
Carvalho, Miguel
Ashdown, Susan P.
Xu, Bugao
Castellucci, Ignacio
Palavras-chave3D body scanners
Kinect
precision
reliability
Traditional anthropometry
Data1-Jan-2017
EditoraIOS Press
RevistaWORK
Resumo(s)BACKGROUND: Understanding the reliability and precision of the data obtained using three-dimensional body scanners is very important if it is intended to replace the traditional data collection methods. If the collection of anthropometric data with three-dimensional body scanners is a fast and reliable process that produces precise data at a low price, it could be used for numerous applications worldwide. Many studies have addressed data collected by white light and laser based scanners. OBJECTIVE: This study provides a comparative analysis between the anthropometric data collected using a Kinect body imaging system with the data collected using traditional manual methods. Moreover, a comparison is also made between the results obtained in this study and the results of previous studies of different types of body scanners. METHODS: The Mean Absolute Difference was calculated and all the values were compared to the maximum allowable error defined in ISO 20685. Additionally, an analysis of the significant differences between the two acquisition methods was also applied to a physical mannequin, to understand how the body movement and body stance variation in human participants impacts the results obtained. RESULTS: There are few body measurements that are close to this restricted allowable error. The results were better when the mannequin was measured. Although they were still above the ISO 20685 limit, they were much closer than the results obtained for human participants. CONCLUSION: The main cause of the differences between the two methods is the time required for the 3D system to acquire the data. The involuntary body sway of human participants is more difficult to control when the time span is too long.
TipoArtigo
URIhttps://hdl.handle.net/1822/55098
DOI10.3233/WOR-172532
ISSN1051-9815
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:CAlg - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
RI74_work.pdf
Acesso restrito!
1,13 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID