Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/52908

TítuloFast left ventricle tracking in CMR images using localized anatomical affine optical flow
Autor(es)Queirós, Sandro Filipe Monteiro
Vilaça, João L.
Morais, Pedro André Gonçalves
Fonseca, Jaime C.
D’hooge, Jan
Barbosa, Daniel Joaquim Cunha
Palavras-chaveCardiac cine MRI
Left ventricle tracking
Localized affine optical flow
Global cardiac function
DataFev-2015
EditoraSociety of Photo-optical Instrumentation Engineers (SPIE)
RevistaProceedings of SPIE
Resumo(s)In daily cardiology practice, assessment of left ventricular (LV) global function using non-invasive imaging remains central for the diagnosis and follow-up of patients with cardiovascular diseases. Despite the different methodologies currently accessible for LV segmentation in cardiac magnetic resonance (CMR) images, a fast and complete LV delineation is still limitedly available for routine use. In this study, a localized anatomically constrained affine optical flow method is proposed for fast and automatic LV tracking throughout the full cardiac cycle in short-axis CMR images. Starting from an automatically delineated LV in the end-diastolic frame, the endocardial and epicardial boundaries are propagated by estimating the motion between adjacent cardiac phases using optical flow. In order to reduce the computational burden, the motion is only estimated in an anatomical region of interest around the tracked boundaries and subsequently integrated into a local affine motion model. Such localized estimation enables to capture complex motion patterns, while still being spatially consistent. The method was validated on 45 CMR datasets taken from the 2009 MICCAI LV segmentation challenge. The proposed approach proved to be robust and efficient, with an average distance error of 2.1 mm and a correlation with reference ejection fraction of 0.98 (1.9 ± 4.5%). Moreover, it showed to be fast, taking 5 seconds for the tracking of a full 4D dataset (30 ms per image). Overall, a novel fast, robust and accurate LV tracking methodology was proposed, enabling accurate assessment of relevant global function cardiac indices, such as volumes and ejection fraction.
TipoArtigo em ata de conferência
Descrição"Progress in Biomedical Optics and Imaging, vol. 16, nr. 41"
URIhttps://hdl.handle.net/1822/52908
ISBN978-162841503-2
DOI10.1117/12.2082017
ISSN0277-786X
e-ISSN1996-756X
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:DEI - Artigos em atas de congressos internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
941306.pdf560,69 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID