Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/39505

TítuloValidation of a method to measure light distortion surrounding a source of glare
Autor(es)Neves, Helena Isabel Ferreira
Araújo, Rute Juliana Ferreira Macedo
Rico-del-Viejo, L.
Silva, Ana Carolina
Queirós, A.
González-Méijome, José Manuel
Palavras-chaveLight distortion
Glare
Haloes
Pupil size
Validation
Data2015
EditoraSociety of Photo Optical Instrumentation Engineers
RevistaJournal of Biomedical Optics
CitaçãoFerreira-Neves, Helena; Macedo-de-Araújo, Rute; Rico-del-Viejo, Laura; da-Silva, Ana C.; Queirós, António; González-Méijome, José M.Validation of a method to measure light distortion surrounding a source of glare, Journal of Biomedical Optics, 20, 7, 075002-075002, 2015.
Resumo(s)Our objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects.
TipoArtigo
URIhttps://hdl.handle.net/1822/39505
DOI10.1117/1.JBO.20.7.075002
ISSN1083-3668
Outros identificadores1083-3668
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.114. FERREIRA-NEVES_15_JBO (LDA Validation).pdf907,21 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID