Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/31339

Registo completo
Campo DCValorIdioma
dc.contributor.authorPoletti, Elisapor
dc.contributor.authorVasconcelos, Graçapor
dc.contributor.authorBranco, Jorge M.por
dc.contributor.authorKoukouviki, A. M.por
dc.date.accessioned2014-11-26T10:38:11Z-
dc.date.available2014-11-26T10:38:11Z-
dc.date.issued2014-10-15-
dc.identifier.urihttps://hdl.handle.net/1822/31339-
dc.description.abstractTimber connections are an important part of a timber structure and a great variability exists in terms of types of connections and mechanisms. Taking as case study the traditional timber frame structures, the half-lap joint was selected. Connections play a major role in the overall behaviour of a structure, particularly when assessing their seismic response, since damage is concentrated at the connections. Therefore, an experimental campaign was carried out on traditional half-lap joints to assess their in-plane response, carrying out pull-out and in-plane cyclic tests. Subsequently, the connections were retrofitted using self-tapping screws, steel plates and GFRP sheets. In this paper, the experimental results are presented taking into account factors such as dissipated energy, damping and influence on the wall behaviour.por
dc.description.abstractAs ligações em madeira constituem uma parte importante das estruturas em madeira e existe uma grande variabilidade em termos de tipologia de ligações e mecânismos. Considerando como caso de estudo os edifícios com paredes de madeira tradicionais (paredes de frontal), foi adotada a ligação madeira-madeira. As ligações tem uma função fundamental no comportamento global da estrutura, em particular na analise sismica, uma vez que o dano é concentrado nas ligações. Portanto, foi executada uma campanha experimental sobre ligações tradicionais madeira-madeira para avaliar o comportamento no plano, realizando ensaios cíclicos e de pull-out. A seguir, as ligações foram reforçadas com parafusos auto-perforantes, chapas metalicas e folhas de fibra de vidro. Neste artigo são apresentados os resultados experimentais considerando factores tal como a dissipação de energia, o amortecimento viscoso e a influencia no comportamento global das paredes de frontal.por
dc.language.isoengpor
dc.publisherUniversidade de Aveiropor
dc.rightsrestrictedAccesspor
dc.subjectTraditional timber connectionspor
dc.subjectIn-plane cyclic testspor
dc.subjectCyclic Pull-out testspor
dc.subjectRetrofittingpor
dc.subjectGFRPpor
dc.subjectSteel platespor
dc.subjectSelf-tapping screwspor
dc.titleMechanical characterization of traditional timber connections: experimental resultspor
dc.title.alternativeCaracterização mecânica de ligações tradicionais em madeira: resultados experimentaispor
dc.typeconferencePaper-
dc.peerreviewedyespor
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate15 - 17 out. 2014por
sdum.event.typecongresspor
oaire.citationConferencePlaceAveiro, Portugalpor
oaire.citationTitle9º Congresso Nacional de Mecânica Experimentalpor
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
sdum.conferencePublication9º Congresso Nacional de Mecânica Experimentalpor
Aparece nas coleções:ISISE - Comunicações a Conferências Nacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
161A.pdf
Acesso restrito!
Paper 161 A1,09 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID