Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/13779

Título“In situ” corneal and contact lens thickness changes with high resolution OCT
Autor(es)González-Méijome, José Manuel
Cerviño, Alejandro
Peixoto-de-Matos, S. C.
Madrid-Costa, David
Jorge, Jorge
Ferrer-Blasco, Teresa
Palavras-chaveCoherence tomography
Cornea
OCT
stromal thickness
epithelial thickness
edema
contact lenses
Data2012
EditoraLippincott, Williams & Wilkins
RevistaCornea
Resumo(s)Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant increase in epithelial thickness in the fellow control eye 30 minutes after insertion (p=0.028). A significant and progressive increase in stromal thickness up to 8% after 90 minutes of lens wear was observed at a constant rate of 2.5% 50 every 30 minutes, being statistically significant in all observations (p<0.001). Fellow control eye also showed a significant increase in stromal thickness at a much lower rate of 0.5% every 30 minutes. Lens thickness decreased significantly by 2% after 90 minutes of lens wear under closed eye conditions (p<0.001). Individual analysis showed that all eyes displayed stromal swelling, while only half of them showed epithelial swelling. Conclusion: Increase in stromal thickness and a slight decrease in lens thickness were observed in response to a hypoxic stimulus under closed eye conditions. High resolution spectral domain HR SOCT is a powerful tool to investigate in vivo the physiological interactions between cornea and contact lenses.
TipoArtigo
URIhttps://hdl.handle.net/1822/13779
DOI10.1097/ICO.0b013e31823f0905
ISSN0277-3740
Versão da editorahttp://journals.lww.com/corneajrnl/pages/default.aspx
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.65b. GONZALEZ-MEIJOME_11_CORNEA (SOCT Epithelial Stromal CL Thickness Changes Overnight).pdf1,04 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID