Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/12360

Registo completo
Campo DCValorIdioma
dc.contributor.authorCastro, André-
dc.contributor.authorCompleto, António-
dc.contributor.authorSimões, José A.-
dc.contributor.authorFlores, Paulo-
dc.date.accessioned2011-05-06T14:45:13Z-
dc.date.available2011-05-06T14:45:13Z-
dc.date.issued2011-
dc.identifier.citationCONGRESSO NACIONAL DE BIOMECÂNICA, 4, Coimbra, Portugal, 2011 – “4º Congresso Nacional de Biomecânica.” [Coimbra : Sociedade Portuguesa de Biomecânica, 2011]. p. 561-566.por
dc.identifier.urihttps://hdl.handle.net/1822/12360-
dc.description.abstractOne of the major reasons for the failure of currently available knee implants is the stress shielding effect. The implant acts as a “shield of loads”, which means that loads are not distributed throughout the bone tissue and, consequently, the rate of bone remodeling decreases. The purpose for this work was to analyze the influence of the geometry and rigidity of the bone-implant interface on the stress shielding effect and on the stability of the prosthesis, applying the Finite Element Method. The results showed that elastic strain is lower on bone areas close to the studied models of patellofemoral prosthesis, on the period after the implantation. When the lifetime of the implant advances, bone rupture by fatigue may occur, due to elevated strain, particularly on the models with fixation pins for the prosthesis. Additionally, contact analyses showed that stability is best promoted without fixation pins.por
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT) - PTDC/EMEPME/67687/2006 "ProPaFe - Design and Development of a Patello-Femoral Prosthesis", bolsa de doutaramento SFRH/BD/63882/2009por
dc.language.isoporpor
dc.rightsrestrictedAccesspor
dc.subjectKneepor
dc.subjectPatellofemoral arthroplastypor
dc.subjectFinite element modelpor
dc.subjectStress shielding effectpor
dc.titleBiomechancal response of new femoral components for patellofemoral arthroplastypor
dc.typeconferencePaper-
dc.peerreviewednopor
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate4-5 Fev. 2011por
sdum.event.typecongresspor
oaire.citationStartPage561por
oaire.citationEndPage566por
oaire.citationConferencePlaceCoimbra, Portugalpor
oaire.citationTitle4º Congresso Nacional de Biomecânicapor
sdum.conferencePublication4º Congresso Nacional de Biomecânicapor
Aparece nas coleções:DEM - Publicações em actas de encontros científicos / Papers in conference proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
ACN33.pdf
Acesso restrito!
Documento principal241,48 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID