Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/43550

Registo completo
Campo DCValorIdioma
dc.contributor.authorGomes, Isabelpor
dc.contributor.authorFotis, Kondispor
dc.contributor.authorSousa, Hélder S.por
dc.contributor.authorBranco, Jorge M.por
dc.contributor.authorLourenço, Paulo B.por
dc.date.accessioned2016-12-19T17:04:43Z-
dc.date.issued2016-08-
dc.identifier.citationGomes I.D., Kondis F., Sousa H.S., Branco J.M., Lourenço P.B. (2016). Assessment and diagnosis of two collar timber trusses by means of visual grading and non-destructive tests. In: Historical Earthquake-Resistant Timber Framing in the Mediterranean Area: HEaRT 2015. Part IV. Lecture Notes in Civil Engineering, vol. 1. Eds: Helena Cruz, José S. Machado, Alfredo C. Costa, Paulo X. Candeias, Nicola Ruggieri, José M. Catarino. Springer International Publishing. pp. 311-320. doi: 10.1007/978-3-319-39492-3_26, ISBN: 978-3-319-39491-6.por
dc.identifier.isbn978-3-319-39491-6-
dc.identifier.isbn978-3-319-39492-3-
dc.identifier.issn2366-2557-
dc.identifier.urihttps://hdl.handle.net/1822/43550-
dc.descriptionPre-print versionpor
dc.description.abstractThe main objective of the present work is to evidence the importance of the inspection and diagnosis phase on the assessment of existing timber structures through visual grading and non-destructive testing (NDT) of its elements, especially for old structures with historical importance. To that aim, two collar timber trusses were inspected and assessed. These trusses were part of an old roof with over than one hundred years old that was decommissioned and then reassembled in laboratory conditions in the University of Minho (Portugal). The timber trusses were then tested on full scale at laboratory conditions until failure. The first part of this work presents the visual grading procedure complemented with NDT. During that part, all the elements of the trusses were visually inspected on each 40 cm segments with consideration of its geometric characteristics (exterior cross-section, wane and deformation), its defects (cracks, knots and decay) and critical sections. Non-destructive techniques, such as impact penetration, ultrasound and drilling resistance tests, were carried out in order to characterize the level of conservation of the elements at its present condition. The combination of the results of all NDTs allowed for a more substantiated grading of the segments and consequently of the elements. The results are presented through damage maps indicating the main pathologies of the structure and its residual cross-section, as well as correlations between different NDTs. In the second part of this work, a comparative analysis between the two trusses is made considering the prior results of the NDTs and the performance of the trusses on the full scale tests. To that aim the results of the visual grading and NDTs are correlated to the sections were failure of the segments was visible.por
dc.description.sponsorshipFP1101 and RILEM TC 245 RTE is acknowledged. The second author acknowledges the grant provided for his STSM within FP1101. The support of the Structural Lab from University of Minhopor
dc.language.isoengpor
dc.publisherSpringerpor
dc.rightsclosedAccesspor
dc.subjectTimber trussespor
dc.subjectVisual gradingpor
dc.subjectNDTspor
dc.subjectDamage mapspor
dc.titleAssessment and diagnosis of two collar timber trusses by means of visual grading and non-destructive testspor
dc.typeconferencePaperpor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://link.springer.com/chapter/10.1007/978-3-319-39492-3_26por
sdum.publicationstatusinfo:eu-repo/semantics/publishedVersionpor
oaire.citationStartPage311por
oaire.citationEndPage320por
oaire.citationTitleHistorical Earthquake-Resistant Timber Framing in the Mediterranean Area: HEaRT 2015. Part IV. Lecture Notes in Civil Engineeringpor
oaire.citationVolume1por
dc.identifier.doi10.1007/978-3-319-39492-3_26por
dc.subject.fosEngenharia e Tecnologia::Engenharia Civilpor
dc.subject.wosScience & Technologypor
sdum.journalLecture Notes in Civil Engineeringpor
sdum.conferencePublicationHISTORICAL EARTHQUAKE-RESISTANT TIMBER FRAMING IN THE MEDITERRANEAN AREApor
sdum.bookTitleHistorical Earthquake-Resistant Timber Framing in the Mediterranean Area: HEaRT 2015. Part IV. Lecture Notes in Civil Engineeringpor
Aparece nas coleções:ISISE - Capítulos/Artigos em Livros Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Assessment and diagnosis of two collar timber trusses.pdf
Acesso restrito!
534,54 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID