TítuloCorrosion behaviour of titanium with oxynitride coatings in physiological solution
Outro(s) título(s)Корозійна поведінка титану з оксинітридними покриттями у фізіологічному розчині
Autor(es)Pohrelyuk, Iryna
Yaskiv, Oleh
Cunha, L.
Palavras-chaveTitanium alloy grade 2
Magnetron sputtering
Diffusion saturation
Oxynitride coatings
Corrosion
Physiological saline
Data6-Jun-2012
EditoraKarpenko Physico-Mechanical Institute of National Academy of Sciences of Ukraine
Resumo(s)In present work the corrosion-electrochemical behavior of titanium alloy Grade 2 with combined coatings - presaturated with nitrogen and oxygen diffusion layer by thermal-chemical treatment and oxynitride coating TiNxOy with nearly equiatomic compositions deposited by magnetron sputtering - in physiological saline (isotonic solution of 0,9% NaCl) was studied. It was found that oxynitride coatings increase the corrosion resistance in 1,2 times as compared to nontreated alloy. When titanium alloy was presaturated with oxygen or nitrogen the combination of oxynitride coating and diffusion layer of thickness 50 μm assists in additional enhancement of corrosion properties in 1,5-3 times.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/21595
Arbitragem científicano
AcessoAcesso aberto
Aparece nas coleções:CDF - GRF - Outros Documentos/Other Documents (without refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Article_Yaskiv-Pohrelyuk-Cunha.pdfaccepted manuscript519,11 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID