TítuloDevelopment of retrofitting solutions: Remedial wall ties for masonry enclosure brick walls
Autor(es)Rebelo, Filipe
Figueiredo, António
Correia Lopes, Gonçalo
Ferreira, Tiago Miguel
Vicente, Romeu
Palavras-chaveinstability and cracking
infill walls
retrofitting
remedial wall ties
out-of-plane
Data2021
EditoraMultidisciplinary Digital Publishing Institute
RevistaBuildings
CitaçãoRebelo, F.; Figueiredo, A.; Correia Lopes, G.; Ferreira, T.M.; Vicente, R. Development of Retrofitting Solutions: Remedial Wall Ties for Masonry Enclosure Brick Walls. Buildings 2021, 11, 28. https://doi.org/10.3390/buildings11010028
Resumo(s)The external envelope walls of a significant percentage of the residential building stock in Southern European countries is commonly constituted by infill masonry walls. However, thousands of square meters of this masonry wall typology presents severe issues of cracking and instability, related to the incorrect and deficient support conditions of the outer brick panel of the double-leaf wall solution. In this work, an experimental campaign divided in two phases has been performed to evaluate the effectiveness of two different remedial wall ties retrofitting techniques (<i>Solution A</i> and <i>Solution B</i>) used for double leaf horizontally hollowed clay brick masonry façades. The first phase of the experimental campaign was performed on 120 isolated specimens of horizontally hollowed clay bricks, resorting to post- and pre-NP EN 771-1 brick exemplars (that is, new and pre-existent aged bricks, respectively), as well as on 4 square wallettes, with a side length of 1.20 m, considered as representative of a real scale scenario, for evaluating the two remedial wall ties retrofitting techniques. The second phase of the experimental campaign was performed to fully characterize the different failure types as well as the slipping phenomena observed in the first phase of the experimental campaign, focusing solely on the retrofitting technique <i>Solution B</i> and comprises 24 tests performed on isolated specimens, resourcing to new and pre-existent aged bricks as well. The results obtained by the use of these techniques revealed an average anchorage strength value ranging from 0.25 to 2.5 kN for each tested tie-bar. <i>Solution B</i> reveals an increase of double of the anchorage strength value in comparison to <i>Solution A</i>. In this sense, the global results revealed a suitable applicability of both retrofit studied solutions.
TipoArtigo
URIhttps://hdl.handle.net/1822/72284
DOI10.3390/buildings11010028
ISSN2075-5309
Versão da editorahttps://www.mdpi.com/2075-5309/11/1/28
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:BUM - MDPI

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
buildings-11-00028-v2.pdf8,47 MBAdobe PDFVer/Abrir

Este trabalho está licenciado sob uma Licença Creative Commons Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID