Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/63109

Registo completo
Campo DCValorIdioma
dc.contributor.authorFertuzinhos, Aureliano Costapor
dc.contributor.authorTeixeira, Marta Albertinapor
dc.contributor.authorFerreira, Miguel Gonçalvespor
dc.contributor.authorFernandes, Ruipor
dc.contributor.authorCorreia, Rossanapor
dc.contributor.authorMalheiro, Ana Ritapor
dc.contributor.authorFlores, Paulopor
dc.contributor.authorZille, Andreapor
dc.contributor.authorDourado, N.por
dc.date.accessioned2020-01-09T14:43:45Z-
dc.date.available2020-01-09T14:43:45Z-
dc.date.issued2020-
dc.identifier.urihttps://hdl.handle.net/1822/63109-
dc.description.abstractThe aim of this study was to undergo a comprehensive analysis of the thermo‐mechanical properties of nasal cartilages for the future design of a composite polymeric material to be used in human nose reconstruction surgery. A thermal and dynamic mechanical analysis (DMA) in tension and compression modes within the ranges 1 to 20 Hz and 30 °C to 250 °C was performed on human nasal cartilage. Differential scanning calorimetry (DSC), as well as characterization of the nasal septum (NS), upper lateral cartilages (ULC), and lower lateral cartilages (LLC) reveals the different nature of the binding water inside the studied specimens. Three peaks at 60–80 °C, 100–130 °C, and 200 °C were attributed to melting of the crystalline region of collagen matrix, water evaporation, and the strongly bound non‐interstitial water in the cartilage and composite specimens, respectively. Thermogravimetric analysis (TGA) showed that the degradation of cartilage, composite, and subcutaneous tissue of the NS, ULC, and LLC take place in three thermal events (~37 °C, ~189 °C, and ~290 °C) showing that cartilage releases more water and more rapidly than the subcutaneous tissue. The water content of nasal cartilage was estimated to be 42 wt %. The results of the DMA analyses demonstrated that tensile mode is ruled by flow‐independent behaviour produced by the time‐dependent deformability of the solid cartilage matrix that is strongly frequency‐dependent, showing an unstable crystalline region between 80–180 °C, an amorphous region at around 120 °C, and a clear glass transition point at 200 °C (780 kJ/mol). Instead, the unconfined compressive mode is clearly ruled by a flow‐dependent process caused by the frictional force of the interstitial fluid that flows within the cartilage matrix resulting in higher stiffness (from 12 MPa at 1 Hz to 16 MPa at 20 Hz in storage modulus). The outcomes of this study will support the development of an artificial material to mimic the thermo‐mechanical behaviour of the natural cartilage of the human nose.por
dc.description.sponsorshipA. Fertuzinhos, Paulo Flores and N. Dourado acknowledge Fundação para a Ciência e a Tecnologia, FCT, for the conceded financial support through the reference project UID/EEA/04436/2013, COMPETE 2020 with the code POCI‐01‐0145‐FEDER‐006941. A. Zille acknowledges financial support of the FCT through an Investigator FCT Research contract (IF/00071/2015) and the project POCI‐01‐0145‐FEDER‐007136 and UID/CTM/00264 under the COMPETE and FCT/MCTES (PIDDAC) co‐financed by European funds (FEDER) through the PT2020 programpor
dc.language.isoengpor
dc.publisherMDPIpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147325/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147331/PTpor
dc.rightsopenAccesspor
dc.subjectCartilagepor
dc.subjectThermo‐mechanical characterizationpor
dc.subjectViscoelasticitypor
dc.subjectNasal soft tissuepor
dc.subjectRhinoplastypor
dc.titleThermo‐mechanical behaviour of human nasal cartilagepor
dc.typearticlepor
dc.peerreviewedyespor
oaire.citationStartPage1por
oaire.citationEndPage22por
oaire.citationIssue177por
oaire.citationVolume12por
dc.identifier.eissn2073-4360por
dc.identifier.doi10.3390/polym12010177por
dc.subject.fosEngenharia e Tecnologia::Engenharia Mecânicapor
dc.subject.fosEngenharia e Tecnologia::Engenharia dos Materiaispor
dc.subject.wosScience & Technologypor
sdum.journalPolymerspor
Aparece nas coleções:DET/2C2T - Artigos em revistas internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2020 Fertuzinhos et al.pdf2,72 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID