dc.identifier.citation"Ophthalmic and physiological optics". ISSN 0275-5408. 27:2 (Mar. 2007) 190-193.eng
dc.identifier.issn0275-5408eng
dc.identifier.urihttp://hdl.handle.net/1822/6199-
dc.description.abstractTo assess the accuracy and repeatability of central corneal thickness (CCT) measurements taken with a new portable ultrasound (US) pachymeter. Methods: Central thickness measurements were taken with a portable pachymeter (SP-100 Handy;Tomey, Nagoya, Japan) and a conventional US pachymeter (Nidek UP-1000; Nidek Technologies, Gamagori, Japan) from 57 right corneas of 57 young adults (19 males, 38 females) aged 18–44 years (mean ± S.D., 22.95 ± 3.92). Three repeated measures were obtained and then compared to obtain the repeatability of each instrument and the agreement between the pachymeters. The three readings taken with the portable pachymeter were compared against each other in order to evaluate intra-session repeatability and bias of each individual measurement with respect to the mean of three. Results: Mean values of CCT were 537 ± 35 micron for conventional and 534 ± 35 micron for the new portable pachymeter. A high agreement was found between the two instruments mean difference = 2.58 micron; 95% CI 1.41–3.75 micron) with only two eyes presenting differences larger than ± 8.6 micron which represents 95% CI in the Bland-Altman plots which represents 1.6% of the mean CCT. The first reading taken showed the highest agreement with the mean value for the portable pachymeter. Conclusions: The instrument tested in this study is able to take reliable measurements of corneal thickness even if a single reading is considered. Intra-session repeatability was very high, as was also the agreement between the average of three readings taken with the two US pachymeters.eng
dc.language.isoengeng
dc.publisherWileyeng
dc.rightsopenAccesseng
dc.subjectPachymeter comparisoneng
dc.subjectPortable ultrasound pachymetryeng
dc.subjectCorneal thicknesseng
dc.titleAccuracy and repeatability of a new portable ultrasound pachymetereng
dc.typearticlepor
dc.peerreviewedyespor
sdum.number2eng
sdum.pagination190-193eng
sdum.publicationstatuspublishedeng
sdum.volume27eng
sdum.journalOphthalmic and physiological opticspor
Appears in Collections:CDF - OCV - Artigos/Papers (with refereeing)

Files in This Item:
File Description SizeFormat 
AQP_OPO_US Pachometry.pdfdocumento principal95,12 kBAdobe PDFView/Open

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID