TitleAccuracy and repeatability of a new portable ultrasound pachymeter
Author(s)Queirós, A.
González-Méijome, José Manuel
Fernandes, Paulo Rodrigues
Jorge, Jorge
Almeida, José B.
Parafita, Manuel A.
KeywordsPachymeter comparison
Portable ultrasound pachymetry
Corneal thickness
Issue dateMar-2007
PublisherWiley
JournalOphthalmic and physiological optics
Citation"Ophthalmic and physiological optics". ISSN 0275-5408. 27:2 (Mar. 2007) 190-193.
Abstract(s)To assess the accuracy and repeatability of central corneal thickness (CCT) measurements taken with a new portable ultrasound (US) pachymeter. Methods: Central thickness measurements were taken with a portable pachymeter (SP-100 Handy;Tomey, Nagoya, Japan) and a conventional US pachymeter (Nidek UP-1000; Nidek Technologies, Gamagori, Japan) from 57 right corneas of 57 young adults (19 males, 38 females) aged 18–44 years (mean ± S.D., 22.95 ± 3.92). Three repeated measures were obtained and then compared to obtain the repeatability of each instrument and the agreement between the pachymeters. The three readings taken with the portable pachymeter were compared against each other in order to evaluate intra-session repeatability and bias of each individual measurement with respect to the mean of three. Results: Mean values of CCT were 537 ± 35 micron for conventional and 534 ± 35 micron for the new portable pachymeter. A high agreement was found between the two instruments mean difference = 2.58 micron; 95% CI 1.41–3.75 micron) with only two eyes presenting differences larger than ± 8.6 micron which represents 95% CI in the Bland-Altman plots which represents 1.6% of the mean CCT. The first reading taken showed the highest agreement with the mean value for the portable pachymeter. Conclusions: The instrument tested in this study is able to take reliable measurements of corneal thickness even if a single reading is considered. Intra-session repeatability was very high, as was also the agreement between the average of three readings taken with the two US pachymeters.
TypeArticle
URIhttp://hdl.handle.net/1822/6199
ISSN0275-5408
Peer-Reviewedyes
AccessOpen access
Appears in Collections:CDF - OCV - Artigos/Papers (with refereeing)

Files in This Item:
File Description SizeFormat 
AQP_OPO_US Pachometry.pdfdocumento principal95,12 kBAdobe PDFView/Open

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID