Please use this identifier to cite or link to this item: http://hdl.handle.net/1822/57717

TitleMicrofluidic deformability study of an innovative blood analogue fluid based on giant unilamellar vesicles
Author(s)Carvalho, Denise A. M.
Rodrigues, Ana Rita Oliveira
Faustino, Vera
Pinho, Diana
Castanheira, Elisabete M. S.
Lima, Rui Alberto Madeira Macedo
KeywordsBlood analogues
Giant unilamellar vesicles
Deformation index
In vitro blood
Biomimetic
Microcirculation
Issue date4-Dec-2018
PublisherMultidisciplinary Digital Publishing Institute (MDPI)
JournalJournal of Functional Biomaterials
CitationCarvalho, D.A.M.; Rodrigues, A.R.O.; Faustino, V.; Pinho, D.; Castanheira, E.M.S.; Lima, R. Microfluidic Deformability Study of an Innovative Blood Analogue Fluid Based on Giant Unilamellar Vesicles. J. Funct. Biomater. 2018, 9, 70.
Abstract(s)Blood analogues have long been a topic of interest in biofluid mechanics due to the safety and ethical issues involved in the collection and handling of blood samples. Although the current blood analogue fluids can adequately mimic the rheological properties of blood from a macroscopic point of view, at the microscopic level blood analogues need further development and improvement. In this work, an innovative blood analogue containing giant unilamellar vesicles (GUVs) was developed to mimic the flow behavior of red blood cells (RBCs). A natural lipid mixture, soybean lecithin, was used for the GUVs preparation, and three different lipid concentrations were tested (1 × 10−3 M, 2 × 10−3 M and 4 × 10−3 M). GUV solutions were prepared by thin film hydration with a buffer, followed by extrusion. It was found that GUVs present diameters between 5 and 7 µm which are close to the size of human RBCs. Experimental flow studies of three different GUV solutions were performed in a hyperbolic-shaped microchannel in order to measure the GUVs deformability when subjected to a homogeneous extensional flow. The result of the deformation index (DI) of the GUVs was about 0.5, which is in good agreement with the human RBC’s DI. Hence, the GUVs developed in this study are a promising way to mimic the mechanical properties of the RBCs and to further develop particulate blood analogues with flow properties closer to those of real blood.
TypeArticle
URIhttp://hdl.handle.net/1822/57717
DOI10.3390/jfb9040070
ISSN2079-4983
e-ISSN2079-4983
Publisher versionhttps://www.mdpi.com/2079-4983/9/4/70
Peer-Reviewedyes
AccessOpen access
Appears in Collections:PHYSICS OF QUANTUM MATERIALS AND BIONANOSTRUCTURES (2018 - ...)

Files in This Item:
File Description SizeFormat 
Manuscript_JFBiomaterials.pdfDocumento principal655,35 kBAdobe PDFView/Open

This item is licensed under a Creative Commons License Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID