Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/51206

Registo completo
Campo DCValorIdioma
dc.contributor.authorRodrigues, Raquel O.por
dc.contributor.authorPinho, Dianapor
dc.contributor.authorBento, D.por
dc.contributor.authorLima, Rui Alberto Madeira Macedopor
dc.contributor.authorRibeiro, Joãopor
dc.date.accessioned2018-02-28T11:07:38Z-
dc.date.available2018-02-28T11:07:38Z-
dc.date.issued2016-
dc.identifier.issn0263-2241por
dc.identifier.urihttps://hdl.handle.net/1822/51206-
dc.description.abstractIntracranial aneurysm is a local dilatation of an intracranial artery with high risk of rupture and death. Although it is generally accepted that the weakening of the arterial wall is the main cause for the rupture of an aneurysm, it still no consensus about the reasons for its creation, expansion and rupture. In particular, what is the role played by the blood flow in these phenomena. In this way, the aim of this work is the in vitro mechanical assessment of the wall expansion, namely the displacements, deformations and strains occurring in a saccular intracranial aneurysm model, when subjected to different flow rates. To obtain new insights into the mechanisms involved in the aneurysm rupture, a 3D-VicTM Digital Image Correlation System was used and validated with a finite element analysis. The wall expansion results have revealed that the displacements, deformations and principal strains are directly related to the internal pressure caused by the fluid on the wall of the aneurism. These findings were especially observed in the weakened areas of the aneurysm model, where the wall was thinner. Furthermore, the technique used in this study has shown to be a potential method to validate numerical simulations of aneurysms, allowing the future performance of more complex and realistic haemodynamic studies.por
dc.description.sponsorshipThe authors acknowledge the financial support provided by PTDC/SAU-ENB/116929/2010, EXPL/EMSSIS/2215/2013 and UID/EQU/50020/2013 from FCT (Fundação para a Ciência e a Tecnologia), COMPETE, QREN and European Union (FEDER). R.O. Rodrigues, D. Pinho and D. Bento acknowledge, respectively, the PhD scholarships SFRH/BD/97658/2013, SFRH/BD/89077/2012 and SFRH/BD/91192/2012 granted by FCT. Also the authors acknowledge the Vic-3DTM DIC System that was kindly borrowed by the University of Coimbra to the experimental execution of this work.por
dc.language.isoengpor
dc.publisherElsevierpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/116929/PTpor
dc.relationEXPL/EMSSIS/2215/2013por
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147286/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F97658%2F2013/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F89077%2F2012/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F91192%2F2012/PTpor
dc.rightsopenAccesspor
dc.subjectAneurysm assessmentpor
dc.subjectFEApor
dc.subject3D digital image correlationpor
dc.subjectValidationpor
dc.titleWall expansion assessment of an intracranial aneurysm model by a 3D digital image correlation systempor
dc.typearticlepor
dc.peerreviewedyespor
oaire.citationStartPage262por
oaire.citationEndPage270por
oaire.citationVolume88por
dc.identifier.doi10.1016/j.measurement.2016.03.045por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technologypor
sdum.journalMeasurementpor
Aparece nas coleções:DEM - Artigos em revistas de circulação internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Rodrigues_et_al_AneurysmModel_Measurement_2016.pdf2,1 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID