Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/49658

TítuloFully Automatic 3D-TEE Segmentation for the Planning of Transcatheter Aortic Valve Implantation
Autor(es)Queirós, Sandro Filipe Monteiro
Papachristidis, Alexandros
Morais, Pedro André Gonçalves
Theodoropoulos, Konstantinos C.
Fonseca, Jaime C.
Monaghan, Mark J.
Vilaça, João L.
D’hooge, Jan
Palavras-chaveAortic valve (AV) segmentation
Automatic initialization
Fully automatic quantification
Transcatheter aortic valve implantation
3-D transesophageal echocardio-graphy (TEE)
Data3-Ago-2017
EditoraInstitute of Electrical and Electronics Engineers (IEEE)
RevistaIEEE Transactions on Biomedical Engineering
CitaçãoQueirós, S., Papachristidis, A., Morais, P., Theodoropoulos, K. C., Fonseca, J. C., Monaghan, M. J., ... & D’hooge, J. (2017). Fully Automatic 3-D-TEE Segmentation for the Planning of Transcatheter Aortic Valve Implantation. IEEE Transactions on Biomedical Engineering, 64(8), 1711-1720
Resumo(s)A novel fully automatic framework for aortic valve (AV) trunk segmentation in three-dimensional (3-D) transesophageal echocardiography (TEE) datasets is proposed. The methodology combines a previously presented semiautomatic segmentation strategy by using shape-based B-spline Explicit Active Surfaces with two novel algorithms to automate the quantification of relevant AV measures. The first combines a fast rotation-invariant 3-D generalized Hough transform with a vessel-like dark tube detector to initialize the segmentation. After segmenting the AV wall, the second algorithm focuses on aligning this surface with the reference ones in order to estimate the short-axis (SAx) planes (at the left ventricular outflow tract, annulus, sinuses of Valsalva, and sinotubular junction) in which to perform the measurements. The framework has been tested in 20 3-D-TEE datasets with both stenotic and nonstenotic AVs. The initialization algorithm presented a median error of around 3 mm for the AV axis endpoints, with an overall feasibility of 90%. In its turn, the SAx detection algorithm showed to be highly reproducible, with indistinguishable results compared with the variability found between the experts' defined planes. Automatically extracted measures at the four levels showed a good agreement with the experts' ones, with limits of agreement similar to the interobserver variability. Moreover, a validation set of 20 additional stenotic AV datasets corroborated the method's applicability and accuracy. The proposed approach mitigates the variability associated with the manual quantification while significantly reducing the required analysis time (12 s versus 5 to 10 min), which shows its appeal for automatic dimensioning of the AV morphology in 3-D-TEE for the planning of transcatheter AV implantation.
TipoArtigo
URIhttps://hdl.handle.net/1822/49658
DOI10.1109/TBME.2016.2617401
ISSN0018-9294
Versão da editorahttp://ieeexplore.ieee.org/abstract/document/7590022/?reload=true
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals
DEI - Artigos em revistas internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2017queiross.pdf759,24 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID