Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/49093

Registo completo
Campo DCValorIdioma
dc.contributor.authorPinto, Vânia C.por
dc.contributor.authorSousa, Paulo J.por
dc.contributor.authorCatarino, Susana Oliveirapor
dc.contributor.authorNeves, Margarida Correiapor
dc.contributor.authorMinas, Graçapor
dc.date.accessioned2018-01-08T16:09:56Z-
dc.date.available2018-01-08T16:09:56Z-
dc.date.issued2017-04-15-
dc.identifier.citationPinto, V., Sousa, P., Catarino, S. O., Correia-Neves, M., & Minas, G. (2017). Microfluidic immunosensor for rapid and highly-sensitive salivary cortisol quantification. Biosensors and Bioelectronics, 90, 308-313por
dc.identifier.issn0956-5663-
dc.identifier.urihttps://hdl.handle.net/1822/49093-
dc.description.abstractThis paper presents a novel poly(dimethylsiloxane) (PDMS) microfluidic immunosensor that integrates a complementary metal-oxide-semiconductor (CMOS) optical detection system for a rapid and highly-sensitive quantification of salivary cortisol. The simple and non-invasive method of saliva sampling provides an interesting alternative to the blood, allowing a fast sampling at short intervals, relevant for many clinical diagnostic applications. The developed approach is based on the covalent immobilization of a coating antibody (Ab), a polyclonal anti-IgG, onto a treated PDMS surface. The coating Ab binds the capture Ab, an IgG specific for cortisol, allowing its correct orientation. Horseradish peroxidase (HRP)-labelled cortisol is added to compete with the cortisol in the sample, for the capture Ab binding sites. The HRP-labelled cortisol, bonded to the capture Ab, is measured through the HRP enzyme and the tetramethylbenzidine (TMB) substrate reaction. The cortisol quantification is performed by colorimetric detection of HRP-labelled cortisol, through optical absorption at 450 nm, using a CMOS silicon photodiode as the photodetector. Under the developed optimized conditions presented here, e.g., microfluidic channels geometry, immobilization method and immunoassay conditions, the immunosensor shows a linear range of detection between 0.01-20 ng/mL, a limit of detection (LOD) of 18 pg/mL and an analysis time of 35 min, featuring a great potential for point-of-care applications requiring continuous monitoring of the salivary cortisol levels during a circadian cycle.por
dc.description.sponsorshipFCT with the reference project UID/EEA/04436/2013, by FEDER funds through the COMPETE 2020 – Programa Operacional Competitividade e Internacionalização (POCI) with the reference project POCI-01-0145-FEDER-006941. V C Pinto thanks the FCT for the SFRH/BD/81526/2011 PhD grant. P J Sousa thanks the FCT for the SFRH/BD/81562/2011 PhD grant. S.O. Catarino thanks the FCT for the SFRH/BPD/108889/2015 grant, supported by national funds from Ministérios da Ciência, Tecnologia e Ensino Superior and by FSE through the POCH - Programa Operacional Capital Humanopor
dc.language.isoengpor
dc.publisherElsevierpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147325/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F81526%2F2011/PTpor
dc.rightsopenAccesspor
dc.subjectMicrofluidic immunosensorpor
dc.subjectColorimetric detectionpor
dc.subjectLab-on-a-chip (LOC)por
dc.subjectPoly(dimethylsiloxane)por
dc.subjectSalivary cortisolpor
dc.titleMicrofluidic immunosensor for rapid and highly-sensitive salivary cortisol quantificationpor
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/journal/09565663por
oaire.citationStartPage308por
oaire.citationEndPage313por
oaire.citationVolume90por
dc.date.updated2017-12-19T16:28:06Z-
dc.identifier.doi10.1016/j.bios.2016.11.067por
dc.identifier.pmid27931005por
dc.subject.fosCiências Médicas::Biotecnologia Médicapor
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technologypor
sdum.journalBiosensors and Bioelectronicspor
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals
DEI - Artigos em revistas internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
untitled.pdf599,03 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID