TitleClinical assessment of the lower tear meniscus height
Author(s)García-Resúa, Carlos
Santodomingo-Rubido, Jacinto
Lira, Madalena
Giraldez, Maria J.
Yebra-Pimentel Vilar, Eva
KeywordsDry Eye Syndromes
Tear film
Fluorescein
Tear meniscus height
Eye piece graticule
Issue dateSep-2009
PublisherCollege of Optometrists
JournalOphthalmic and Physiological Optics
Abstract(s)Purpose: Different values of the lower tear meniscus height (TMH) can be obtained depending on the method and technique of measurement employed. This study aimed to assess (1) differences between the absolute (TMH-A), reflex (TMH-R) and fluorescein (TMH-F) lower tear meniscus heights, (2) differences between the central (TMH-R), nasal (TMH-RN) and temporal (TMH-RT) reflex lower tear meniscus heights and (3) the amount of fluorescein present in the lower tear meniscus, 5 min after fluorescein instillation (TMH-FV). Methods: Thirty four young healthy subjects were included in the study. The lower tear meniscus height (TMH) was measured using an eye piece graticule inserted into a slit-lamp. Results: Mean ± S.D. values of TMH-A, TMH-R, TMH-RN, TMH-RT, TMH-F and TMH-FV of 0.25 ± 0.08, 0.13 ± 0.05, 0.23 ± 0.06, 0.21 ± 0.05, 0.27 ± 0.11 and 0.004 ± 0.001 mm, respectively were found. The TMH-R was significantly lower than the TMH-A and the TMH-F (p < 0.0001). The TMH-RN and TMH-RT were significantly higher than the TMH-R (p < 0.0001). The TMH-F was significant higher than the TMH-FV (p < 0.0001). No significant differences were found between the TMH-A and TMH-F (p = 0.2), and between the TMH-RN and TMH-RT (p = 0.36). Conclusion: Careful instillation of fluorescein does not affect normal TMH values. Fluorescein is washed out from the lower tear meniscus 5 min after instillation. Higher values of the TMH can be found at nasal and temporal locations compared to the center of the lower eye lid.
Typearticle
URIhttp://hdl.handle.net/1822/47594
DOI10.1111/j.1475-1313.2009.00634.x
ISSN0275-5408
e-ISSN1475-1313
Peer-Reviewedyes
AccessclosedAccess
Appears in Collections:CDF - OCV - Artigos/Papers (with refereeing)

Files in This Item:
File Description SizeFormat 
Clinical assessment of the lower tear.pdf282,24 kBAdobe PDFView/Open    Request a copy!

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu Currículo DeGóis