Utilize este identificador para referenciar este registo: http://hdl.handle.net/1822/46110

TítuloThermal performance of lightweight steel framed wall: the importance of flanking thermal losses
Autor(es)Santos, P.
Martins, C.
Silva, Luís Simões da
Bragança, L.
Palavras-chaveLightweight steel framing walls
Thermal transmittance
Flanking heat losses
Experimental measurements
Three-dimensional numerical assessment
Data2013
EditoraSage Publications
RevistaJournal of Building Physics
CitaçãoSantos P., Martins C., Silva S. L., Bragança L. Thermal performance of lightweight steel framed wall: The importance of flanking thermal losses, Journal of Building Physics, Vol. 38, Issue 1, pp. 81-98, doi:10.1177/1744259113499212, 2013
Resumo(s)The thermal performance of a modular lightweight steel framed wall was measured and calculated with three-dimensional finite element method model. The focus of this article is on the effect of flanking thermal losses. The calculated heat flux values varied from ?22% (external surface) to +50% (internal surface) when flanking loss was set to 0 as a reference case, thermal transmittance equal to 0.30 W/(m2·K). Other critical parameters were the existence of fixing ?L?-shaped steel elements and the perimeter thermal insulation (10 cm XPS).
Tipoarticle
Descrição"First Published August 21, 2013"
URIhttp://hdl.handle.net/1822/46110
DOI10.1177/1744259113499212
ISSN1744-2591
e-ISSN1744-2583
Arbitragem científicayes
AcessoopenAccess
Aparece nas coleções:C-TAC - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2629-10-1744259113499212.pdf3,67 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu Currículo DeGóis