Title: | Calibration of a multi-load cells weighing system based on neural networks |
Author(s): | Tavares, Adriano Correia, J. H. Couto, Carlos |
Keywords: | Calibration Load cells |
Issue date: | Oct-1995 |
Citation: | ICSPAT 95 - INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING APPLICATIONS AND TECHNOLOGY, Boston, 1995 - "International Conference on Signal Processing Applications and Technology: Proceedings". [S.l. : s.n., 1995] p. 1290-1295. |
Abstract(s): | Multi-load cells weighting systems are based on a platform supported by four or more load cells, normally in parallel inputting lhe same signal conditioning unit. Because of mechanical and electrical paralleling tuning the gain of a load cell affects lhe behavior of the others, making the calibration difficult and tedious, specially withweightbridges for cars and trucb, requiring lhemotion of heavy weights around /arge p/atforms. |