Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/43588

Registo completo
Campo DCValorIdioma
dc.contributor.authorAndrade, R.por
dc.contributor.authorVasta, S.por
dc.contributor.authorPereira, R.por
dc.contributor.authorPereira, H.por
dc.contributor.authorPapalia, R.por
dc.contributor.authorKarahan, M.por
dc.contributor.authorOliveira, J. M.por
dc.contributor.authorReis, R. L.por
dc.contributor.authorEspregueira-Mendes, Joãopor
dc.date.accessioned2016-12-21T11:24:32Z-
dc.date.issued2016-10-
dc.date.submitted2016-10-
dc.identifier.citationAndrade R., Vasta S., Pereira R., Pereira H., Papalia R., Karahan M., Oliveira J. M., Reis R. L., Espregueira-Mendes J. Knee donor-site morbidity in mosaicplasty - A systematic review, Journal of Experimental Orthopaedics, doi:10.1186/s40634-016-0066-0, 2016por
dc.identifier.issn2197-1153por
dc.identifier.urihttps://hdl.handle.net/1822/43588-
dc.description.abstractBackground: Mosaicplasty has been associated with good short- to long-term results. Nevertheless, the osteochondral harvesting is restricted to the donor-site area available and it may lead to significant donor-site morbidity. Purpose: Provide an overview of donor-site morbidity associated with harvesting of osteochondral plugs from the knee joint in mosaicplasty procedure. Methods: Comprehensive search using Pubmed, Cochrane Library, SPORTDiscus and CINAHL databases was carried out through 10th October of 2016. As inclusion criteria, all English-language studies that assessed the knee donor- site morbidity after mosaicplasty were accepted. The outcomes were the description and rate of knee donor-site morbidity, sampleâ s and cartilage defectâ s characterization and mosaicplasty-related features. Correlation between mosaicplasty features and rate of morbidity was performed. The methodological and reporting quality were assessed according to Colemanâ s methodology score. Results: Twenty-one studies were included, comprising a total of 1726 patients, with 1473 and 268 knee and ankle cartilage defects were included. The defect size ranged from 0.85 cm2 to 4.9 cm2 and most commonly 3 or less plugs (averaging 2.9 to 9.4 mm) were used. Donor-site for osteochondral harvesting included margins of the femoral trochlea (condyles), intercondylar notch, patellofemoral joint and upper tibio-fibular joint. Mean donor-site morbidity was 5.9 % and 19.6 % for knee and ankle mosaicplasty procedures, respectively. Concerning knee-to-knee mosaicplasty procedures, the most common donor-site morbidity complaints were patellofemoral disturbances (22 %) and crepitation (31 %), and in knee-to-ankle procedures there was a clear tendency for pain or instability during daily living or sports activities (44 %), followed by patellofemoral disturbances, knee stiffness and persistent pain (13 % each). There was no significant correlation between rate of donor-site morbidity and size of the defect, number and size of the plugs (p > 0.05). Conclusions: Osteochondral harvesting in mosaicplasty often results in considerable donor-site morbidity. The donor-site morbidity for knee-to-ankle (16.9 %) was greater than knee-to-knee (5.9 %) mosaicplasty procedures, without any significant correlation between rate of donor-site morbidity and size of the defect, number and size of the plugs. Lack or imcomplete of donor-site morbidity reporting within the mosaicplasty studies is a concern that should be addressed in future studies.por
dc.description.sponsorship(undefined)por
dc.language.isoengpor
dc.publisherSpringerOpenpor
dc.rightsopenAccesspor
dc.subjectMosaicplastypor
dc.subjectSystematic reviewpor
dc.subjectArticular cartilage lesionspor
dc.subjectDonor-site morbiditypor
dc.subjectKneepor
dc.subjectOsteochondralpor
dc.titleKnee donor-site morbidity in mosaicplasty - A systematic reviewpor
dc.typearticle-
dc.peerreviewedyespor
dc.commentshttp://3bs.uminho.pt/node/18875por
sdum.publicationstatusinfo:eu-repo/semantics/publishedVersionpor
oaire.citationIssue1por
oaire.citationTitleJournal of Experimental Orthopaedicspor
oaire.citationVolume3por
dc.date.updated2016-12-14T14:54:18Z-
dc.identifier.doi10.1186/s40634-016-0066-0por
sdum.journalJournal of Experimental Orthopaedicspor
Aparece nas coleções:3B’s - Artigos em revistas/Papers in scientific journals
ICVS - Artigos em revistas internacionais / Papers in international journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
18875-Donor-site morbidity.pdf1,12 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID