Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/4315

Registo completo
Campo DCValorIdioma
dc.contributor.authorRocha, J. G.-
dc.contributor.authorSchabmueller, C. G. J.-
dc.contributor.authorRamos, N. F.-
dc.contributor.authorLanceros-Méndez, S.-
dc.contributor.authorEvans, A. G. R.-
dc.contributor.authorWolffenbuttel, R. F.-
dc.contributor.authorCorreia, J. H.-
dc.date.accessioned2006-02-02T15:52:36Z-
dc.date.available2006-02-02T15:52:36Z-
dc.date.issued2002-
dc.identifier.citationINTERNATIONAL CONFERENCE ON INFORMATION SOCIETY TECHNOLOGIES FOR BROADBAND EUROPE (BBE), Bucharest, 2002 - "International Conference on Information Society Technologies for Broadband Europe". Bucharest: European Commission, 2002. p.326-326.eng
dc.identifier.urihttps://hdl.handle.net/1822/4315-
dc.description.abstractThis paper reports the design, fabrication, assembly and testing of a xray detector based on a bulk micromachined photodiode (BMMPD) with a cavity filled with a scintillating crystal. The xray photons that reach the detector are first converted to visible light by the scintillating crystal. The visible light is then detected by the BMMPD, producing an electric current whose value is proportional to the incident xray intensity. The tests are done using a xray tube powered with a voltage of 35 kV, and a current ranging from 0 mA to 1 mA. With this setup, very promising results were obtained. may be divided into three classes: Dose reduction, image processing and display in real time, and flexibility in image storage and retrieval. The first advantage of digital radiography is the possibility of dose reduction. In conventional radiology, the dose is determined by the sensitivity ofeng
dc.description.sponsorshipThis work was supported by the Foundation Science and Technology, Portugal: FCT-CTM/POCTI/33751/1999; Grant-BD SFRH/BD/1296/2000.eng
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectX-rayseng
dc.subjectBMMPDeng
dc.subjectScintillatoreng
dc.subjectRadiographyeng
dc.subjectMicromachiningeng
dc.titleXray detector based on bulk micromachined photodiodeeng
dc.typeconferencePapereng
dc.peerreviewedyeseng
Aparece nas coleções:DEI - Artigos em atas de congressos internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Gr_mme.pdf171,44 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID